CHAPTER 9 EXTERNALS / AUXILIARY MECHANISMS
11) Remove the static eliminator brush.[13][13] [12][13]
12) Disconnect the two connectors [12], and
remove the seven screws [13]; then,
detach the drum motor assembly [14]
together with the fixing plate.
13) Remove the four screws, and detach the
drum motor from the mounting plate.
[14]
[13] [13]
Figure 9-730
2. Mounting the Drum Motor
Assembly[2][1]
When the drum motor assembly is
removed from the copier, be sure to adjust its[4]
position using the drum shaft position tool
(FY9-3045) when mounting it back to
eliminate any discrepancy.
1) Slide out the photosensitive drum unit
from the copier.
2) Remove the six screws [1], and detach the[3]
photosensitive drum butting block [2]
(front, rear); then, detach the
photosensitive drum [3] from the
photosensitive drum frame unit [4].[1][2]
Figure 9-731
[6][5][6][6]
3) Insert the photosensitive drum frame unit
[5] in the copier, and mount it with three
screws [6].
Figure 9-732
9-30COPYRIGHT ? 2002 CANON INC. CANON CLC1100/1130/1150/1160/1180 REV.2 DEC. 2000 PRINTED IN JAPAN (IMPRIME AU JAPON) |