3-1-2. Precautions on Adjusting3-1-3. Adjusting Connectors
Note1: TR model / TRV modelSome of the adjusting points of the video section are concentrated
TR model: CCD-TR317/TR517at VC-234 board CN982. Connect the measuring instruments via
TRV model: CCD-TRV17/TRV37/TRV47/TRV57/TRV57P/the CPC-7 jig (J-6082-382-A). The following table lists the pin
TRV67/TRV87/TRV87P
numbers and signal names of CN982.
1) The adjustments of this unit are performed in the VTR modePin No.Signal NamePin No.Signal Name
or camera mode.1LANC SIG9RF AGC OUT
To set to the VTR mode, set the power switch to OVTR or2XCPC IN10REC RF
PLAYER� or set the OForced VTR Power ON mode� using the
3IR VIDEO11RF SWP
adjustment remote commander (Note 2).4AFC F012CAP FG
To set to the Camera mode, set the power switch to OCAMERA�
or set the OForced Camera Power ON mode� using the5BPF MONI13EVF BL
adjustment remote commander (Note 3).6PB RF14EVF BL 4.75V
After completing adjustments, be sure to exit the OForced VTR7RF AGC IN15VCO
Power ON Mode� or OForced Camera Power ON Mode�. (Note 4)8REG GND16EVF VG
2) By setting the OForced VTR Power ON mode� or OForced
Camera Power ON mode�, the video section can be operateTable 5-3-1.
even if the front panel block (MA-374/375 board, power switch,
microphone unit) has been removed. When removing the front
panel block, disconnect the following connector.
1. VC-234 board CN972 (20P 0.5mm)CN982
1
3) The cabinet (R) (Camera function switch (CF-66/67 board),
LCD block (TRV model only), Viewfinder) need not be
connected. But removing the cabinet (R) (removing the VC-16
234 board CN975) means removing the lithium 3V power
supply (CF-66/67 board BH001), data such as date, time, user-
set menus will be lost. After completing adjustments, reset these
data. If the cabinet (R) has been removed, the self-diagnosis
data, data on history of use (total drum rotation time etc.) will
be lost. Before removing, note down the self-diagnosis data
and data on history use (data of page: 2, address: A2 to AA).
(Refer to the OService Mode� for the data on the history use.)
To remove the cabinet (R), disconnect the following connectors.Screw driver (�)
1. VC-234 board CN975 (45P, 0.5mm)
2. DD-134 board CN933 (8P, 1.0mm)(TRV model only)
4) The video light board (VL-29 board) need not be connected.
To remove, disconnect the following connector. (Except for
CCD-TR317/TR517/TRV47)
1. VL-29 board CN151 (8P, 0.5mm)
5) The lens block (CD-239/240 board) need not be connected. ToCPC lid (BT)
remove, disconnect the following connectors.
Fig. 5-3-1.
1. VC-234 board CN501 (14P, 0.5mm)
2. VC-234 board CN551 (24P, 0.5mm)
Note2: Setting the OForced VTR Power ON� mode (VTR mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the VTR power to be turned
on with the front panel block removed.
After completing adjustments, be sure to exit the OForced VTR
Power ON mode�.
Note3: Setting the OForced Camera Power ON� mode (Camera mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the front panel block removed.
After completing adjustments, be sure to exit the OForced
Camera Power ON mode�.
Note4: Exiting the OForced Power ON� mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
5-40 |