Y ENCODER Ca BIST Check1-6. Processing after Completing Playback System
Order Page Address DataProcedure Check
13108D Set the data, and press PAUSE
button.Order Page Address DataProcedure
100101Set the data.
231210Set the data, and press PAUSE
button.2C42Set the following data, and press
331200Set the data, and press PAUSEPAUSE button.
00: DCR-PC4E
button.
431304Set the data, and press PAUSE28: DCR-PC5/PC5E
button.382103Set the data, and press PAUSE
button.
5314Check that the data is equal to
either of the following values.400100Set the data.
And memorize the case number5Turn off the power and turn on
of the value.again.
NTSC model:
11 (Case1), 4E (Case2)
PAL model:
E8 (Case1), 7B (Case2)
6315Check that the data is equal to
the following value which case
number is equal to that of
address 14.
NTSC model:
FD (Case1), 3B (Case2)
PAL model:
62 (Case1), B0 (Case2)
73If the data of address 14 and
address 15 are correct, IC301
ENCODER Ca playback system
is normal.
Y ENCODER Cb BIST Check
Order Page Address DataProcedure
13108E Set the data, and press PAUSE
button.
231210Set the data, and press PAUSE
button.
331200Set the data, and press PAUSE
button.
431304Set the data, and press PAUSE
button.
5314Check that the data is equal to
either of the following values.
And memorize the case number
of the value.
NTSC model:
5C (Case1), BC (Case2)
PAL model:
96 (Case1), 35 (Case2)
6315Check that the data is equal to
the following value which case
number is equal to that of
address 14.
NTSC model:
20 (Case1), A8 (Case2)
PAL model:
79 (Case1), 7C (Case2)
73If the data of address 14 and
address 15 are correct, IC301
ENCODER Cb playback system
is normal.
5-51 |