F770D Technical Service Manual
4-6 Focus
- Video Signal : Reverse " Full H " character pattern in 64kHz 1024 mode
- Adjust H/V Focus VR on the top and middle of the FBT so that the image of whole
screen looks clear
5. X-Ray Protection Test
- In any signal input condition, short RH11 (main board) by using the JIG.
- At this moment, check out whether raster disappears.
- Remove the JIG.
- After the power switch of the set off and on, check out proper working
6. AGING and Self Test Mode
The monitor has an enhanced level of self-diagonostics.
When the signal cable is removed The monitor is operated to self test mode(Following
OSD Image) and The Signal Isnt detected, the monitor is operated to OFF-Mode.
Picture A (MODE FOR END USER)
1024 768/ 75Hz
NO SIGNAL
RGB
(OSD MESSAGE is moving around the screen)
NO SIGNAL
--17-- |