Introduction5. Turn the cupboard back over and stand it on the top of the cooker hood and
fasten the hood to the cupboard by means of four screws screwed through
These instructions are designed to tell you of the various technical details ofthe holes that were drilled in the bottom of the cupboard (fig. 7/3).
your cooker hood and to make you familiar with its use.Since these instructions
cover more than one type of hood within the same series, it may be that referenceElectric connection
Make sure the supply voltage ratings correspond with those stated on the
is made to components that do not form part of the hood that you are installing.appliance data plate.
Fittings can vary from country to country. We reserve the right to modify the
product without any notice always with the aim of improvements and inThis appliances is double insulated, do not connect to earth.
Attention: If the appliance does not have a plug, when making a fixed
compliance with the relevant norm.installation, a cutoff device must be used to assure omnipolar disconnection
General description
The appliance can be used as a canopy hood or can be mounted beneath athe mains. The cutoff distance of the contacts must be at least 3 mm. If the
wall cupboard and is suitable for use as an exhaust hood or as a recirculatingappliance is provided with a supply cord and plug, the appliances must be
positioned so that the plug is accessible.
hood; if an exhaust facility (an exhaust duct or a ventilating shaft) is available,
then we recommend the hood be installed as an exhaust hood for then, most
of the smells and vapors that arise when cooking or frying can be almostSafety rules
completely removed from the kitchen. The grease filter that is fitted removes anyDo not do any flambe cooking underneath the hood. When frying, never
grease particles from the vapors so that your kitchen, the kitchen furniture andleave the pan alone because the cooking oil could flare up. Clean all the
the walls remain for the most part free of grease and other particles that couldsurfaces frequently to avoid danger of fire. It is also important to remove
give rise to unpleasant odours.and clean or substitute frequently the filter installed in the hood.
Exhaust version
The hood must be connected by the flange (supplied as part of the hood) toMaintenance
a duct to vent all the exhausted air outside the kitchen.Over horizontal areas,N.B. When performing maintenance operations, disconnect the plug from the
if any, the duct must be slanted about 10% upwards from upstream tosocket. Vapors and odors in the air are exhausted first through the grease filter
downstream. Pease make sure that the lever (fig. 6/2) is in the exhaust position.
and then (if the hood is in filter version) through the odor filter. The efficiency
N.B. The efficiency of the exhaust hood decreases as the length of the ductsof the appliance depends on the condition of the filters.
and number of elbows increase.When using the exhaust version, follow theseGrease filter
rules: Do not connect the exhaust hood to chimneys, flues, and air ducts serving
the room.This absorbs vapor-suspended grease particles and protects the kitchen and
furniture from greasy residues. There are three types of filter:
Before venting into exhaust flues and ducts no longer in use, ask for the1. Acrylic. It can be washed at more or less frequent intervals depending on
approval of the person or agency responsible for the building. The evacuated
air must not be let into a warm air duct.For the evacuation of the exhausted airhow often the hood is used. In any case, it should be washed every thirty
days of hood operation. To do so, wash the filter by hand in warm soapy
please note ufficial instructions.water (do not wring the filter; press it in a cloth to dry).
Suggestions for using the hood in exhaust position
When an exhaust hood and a heat source requiring ambient air (e.g. gas, oil,2. Special paper (with coloured signs on the upper sureface ot the filter). Not-
washable: the filter must be changed, when the signs will be visible from
coal stoves, etc.) are used at the same time, attention is required because thebelow through the grille holes.
air necessary for combustion is exhausted from the room through the hood and3. Aluminum layers. The filter should be washed every 10 to 15 days (in normal
this creates depression. There is no such danger when the maximum depression
operating conditions). If the grease filter should change its colour it will not
in the room is 0,04 mbar. In this condition no exhaust gas from the heat sourcehave any effect on its function it will may increase it. Dip the filter into a
is piped. To assure this condition, make openings in the room which cannot bedegreaser solution or put it in the dish washer. Make sure not to damage
closed (doors, windows, etc. are not sufficient) and through which the air
necessary for combustion can freely flow.the filter, which is made of several layers of thin alloy, by hitting or crushing
it.
Note: ? All the exhaust ductwork in the apartment or house should be studied.Active carbon odor filter
In case of doubts, get advice or authorization from the person or agency
responsible for the building.Attention: The filter should only be used in filter hoods. The exhausted air
passes through the active carbon filter and is cleaned. This filter cannot be
Filter versionwashed and must be replaced depending on how often the hood is used (about
This version is used when no exhaust duct to the outdoors is available. The air
is purified by an active vegetable carbon filter and recycled into the room. Maketwice a year). Clean the outside of the hood with a sponge soaked with liquid
neutral detergent. Do not use products containing abrasives.
sure the carbon odor filter is inserted.Replacing the grease filter
Using the cooker hood1. The hood is isolated from the electric supply by withdrawing the power plug.
2. In order to open the grid press the clips (fig. 4/1) at the left and at the right
The cooker hood should be switched on either before or at the same as cookingone towards the other.
or frying commences. Before using the cooker hood please ensure that all3. Tilt the filter frame downwards and push the frame forewards on one side
plastic films like on metal grease filter an stainless steel ducting are removed.of the guide and disengage it from the groove.
The grease and carbon filters are more effective if the fan is not switched off4. The two ends of the wire yoke are then pressed outwards and lifted upwards
immediately after cooking or frying is completed, but only after a period of some(fig. 5). The filter felt can then be removed.
20-30 minutes.After cleaning the grease-filter frame, the new grease filter to be inserted or filter
How the cooker hood worksfelt is cut to size and fitted in the frame.
The hood is fitted with a slide-swicht for speed and light regulation (fig. 3/1).Replacing the active carbon filter
Preparing the cooker hood for use as a recirculation hood(only for recirculation hoods)
If the hood is to be used as a recirculation hood the opening must be closedFor the substitution, please turn the filter counter clockwise (fig. 6/1).
with the cover which is provided. The hood is then switched over from exhaustN.B. The lamps must be only "candle" - type.
to recirculation by moving the lever (that is located beneath the lamp) to the leftNever use lamps with higher rating that indicate on the cover.
(fig. 6/2).What to do in the case of a defect?
When installing the hood and when it is in use, it must be ensured that theIn the case of a service call, please give your service agent the following
opening at the top to the front of the hood is always unobstructed.information:
InstallationModel
Type
The hood must be mounted over the center of the cooking area. The minimum
distance between the cooker and the bottom of the hood must be 650 mm forManuf.-No.
electric cookers and 750 mm for gas cookers. If there is no outer waste-pipeYou will find this information on the type plate, situated next to the
for the exhaust version, an air outlet with a diameter of 130 mm must be made
through the wall.ventilation motor. Enter the numbers immediately into the appropriate
boxes. This information will enable the service agent to prepare the
N.B. The distances, however, are subject to the safety rules in effect in thenecessary spare parts in advance, so that your cooker hood can be
various countries.
Fastening the cooker hood to the wallrepaired on the first service visit.
1. Using fig.8 to draw the fixing holes onto the wall. Before drilling make sureTechnical data
Linking value: motor 1 x 130 W
that no wiring will be damaged.
2. Drill the two fastening holes, drive in the wall plugs and screw in the screwsLighting: 1 x 40 W
until their heads are about 6 mm from the wall (fig. 7/1).Total value: 170 Watt / 230 V / 50 Hz
Electric linking: fixed electric cable 0,9 m with safety plug. In case of
3. Place the hood to the wall in order to check that it seats properly.interventions remove the plug!
Than mark the position of the two holes (fig. 7/2). Take it off from the wall
now, drill the homes and fit the plugs.Power: 220 m3/h max.
4. Place the hood once again to the wall, tighten the screws (fig. 7/1) and
introduce the screws (fig. 7/2) from the inside of the appliance.
Fastening the cooker hood beneath a wall cupboard
1. Turn the wall cupboard upside down.
2. Using fig.8 to mark on the cupboard the positions of the 4 screws holes and
the exhaust opening.
3. Using a 4.5 mm bit, drill the four fastening holes in the bottom of the cupboard.
4. Only for hoods with an exhaust connection pointing upwards.
Cut the exhaust opening for a pipe of (130 mm diameter) and fasten the pipe
flange to the hood.10401250350/01 |