Connection shall be by means of an appliance
Right angled
flexible connector for use with a self-sealingbayonet socket
incorporatingDistribuitor
plug-in device, complying with:
spring loadedpipe
Flexible hoses, end fittings and sockets forAdaptorvalve
backplate
gas burning appliances - BS 669;Female
Copper pipeelbow
- The appliance flexible connector should not
be subjected to undue forces either in
normal use or whilst connected or
disconnected; The socket which the plug of
the appliance flexible connector fits should
be permanently attached to a firmly fixed
Alternative
gas installation pipe and positioned suchbackplate
that the appliance flexible connector hoseelbow
hangs freely downwards (see fig. 27);Cooker hose with
- The appliance flexible connector should bebayonet fixing
positioned such that it will not suffer
mechanical damage, e.g. abrasion from the
surrounding kitchen furniture, which may be
moved in use such as a drawer or door, orStraight bayonetCooker hose with
by being trapped by any stability device.socketbayonet fixing
incorporating
The plug-in-connector should be accessiblespring loaded
for disconnection after moving thevalve
appliance.
CONVERSION OF GAS
Your cooker is designed to work with natural gas,
and is convertible for use with propane or butane.
The LPG conversion kit is available from your
Service Force Centre and must be fitted by a
Corgi Registered engineer.
For changing the gas type it is necessary to:
" replace the nozzles (hob, oven and grill);
" adjust the minimum level (hob and oven);
" adjust the primary air (oven and grill);
" check the gas connection;
Stick the label supplied with the
appliance (in the nozzles bag) corresponding
to the gas type utilised.
Replace the nozzles of the hob burners
Every appliance has spare nozzles for every type
of gas. The whole length of every nozzle is
marked in millimetres on the nozzle.
Hob burners
" Remove the pan support;
" Remove the caps and the burner crowns;
" Using a No 7 socket spanner unscrew the
nozzles and replace them with those required
for the type of gas in use (see table no. 1).
Reassemble the parts following the same
procedure in reverse.
These burners do not need any primary air
regulation.
22 |