14AG2-SMK3-A
No. Adjustment pointAdjustment procedure/conditionsWaveform and others
3SUB-1) In Window Pattern Signal condition.
WINDOW PATTERN SIGNAL
BRIGHTNESS
2) Using Minolta Color Analyzer CA-100, let the
(to be done
gun point at Dark White position (as attach
after screen,
drawing), adjust V06 Bus data until LUMI-
white balance
NANCEY=3 0.5 cd/m2.
adj)
2
(IC BUS
CONTROL)
Dark White
4SUB-1) In Window Pattern Signal condition.
WINDOW PATTERN SIGNAL
CONTRAST
2) Using Minolta Color Analyzer CA-100, let the
(to be done
gun point at White position (as attach drawing),
after screen,
adjust V04 Bus data until LUMINANCE Y = 200
white balance
? 10cd/m2
adj,
sub-bright-
ness adj)
2
(IC BUS
CONTROL)
White
5Beam Current1) Receive the Monoscope Pattern signal.
Check2) Press R/C to set Picture NORMAL condition.
3) Connect the DC miliammeter between TP 603
(+)& TP 602(-).
(Full Scale: 3mA Range)
4) Beam current must be within 800 ? 100?A.
3 - 18 |