3-1-2. Precautions on Adjusting3-1-3. Adjusting Connectors
1) The adjustments of this unit are performed in the Some of the adjusting points of the video section are concentratedVTR mode or
camera mode.at VC-195 board CN910. Connect the measuring instruments via
To set to the VTR mode, set the power switch to the CPC-7 jig (J-6082-382-A). OPLAYER� orThe following table lists the pin
set the OForced VTR Power ON mode� using the adjusting rnumbers and signal names of CN910.emote
commander (Note 1).
To set to the Camera mode, set the power switch to OCAMERA�Pin No.Signal NamePin No.Signal Name
or set the OForced Camera Power ON mode� using the adjusting1LANC SIG9RF AGC OUT
remote commander (Note 2).2XCPC IN10REC RF
After completing adjustments, be sure to exit the 3 OForced IR VIDEOVTR11RF SWP
Power ON Mode� or OForced Camera Power ON Mode�.4AFC F012CAP FG
(Note 3)5BPF MONI13EVF BL
2) The front panel block (MA-332 board, focus ring, microphone6PB RF14EVF BL 4.75V
unit) need not be connected. When removing the fr7 ont panelRF AGC IN15VCO
block disconnect the following connector.8REG GND16EVF VG
1. VC-195 board CN903 (23P 0.5mm)
3) The lens block (CD-200 board, VP-48 board) need not beTable 5-3-1.
connected except during battery end adjustment. To remove,
disconnect the following connectors.
1. VC-195 board CN501 (16P, 0.5mm)
2. VC-195 board CN551 (23P, 0.5mm)
3. VP-48 board CN602 (12P, 0.5mm)
4) The intelligent accessory shoe need not be assembled. If
removing it. disconnect the following connector.
1. VC-195 board CN909 (10P, 0.5mm)
5) By setting the OForced VTR Power ON mode� or OForced
Camera Power ON mode�, cabinet (R) ( Camera function switch
(CF-54 board), LCD block, viewfinder, power switch) need notScrew driver(�)
be connected. But removing the cabinet (R) (removing the VC-
195 board CN911) means removing the lithium 3V power supply,
data such as date, time, user-set menus will be lost. After
completing adjustments, reset these data. If the cabinet (R) has
been removed, the self-diagnosis data, data on history of use
(total drum rotation time etc. ) will be lost. Before removing,
note down the self-diagnosis data and data on the history useCover.
(Refer to the OService Mode� for the data on the history use.) To
remove the cabinet (R), disconnect the following connectors.
1. VC-195 board CN911 (50P, 0.5mm)
2. DD-105 board CN933 (11P, 1.0mm)Fig. 5-3-1.
Note 1:Setting the OForced VTR Power ON� mode
(VTR mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press
the PAUSE button of the adjusting remote
commander.
The above procedure will enable the VTR power to be
turned on with the front panel block removed.
After completing adjustments, be sure to exit the
OForced VTR Power ON mode�.
Note 2:Setting the OForced Camera Power ON� mode
(Camera mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press
the PAUSE button of the adjusting remote
commander.
The above procedure will enable the camera power
to be turned on with the front panel block removed.
After completing adjustments, be sure to exit the
OForced Camera Power ON mode�.
Note 3:Exiting the OForced Power ON� mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjusting remote
commander.
3) Select page: 0, address: 01, and set data: 00.
5-33 |