PHENOMENONACTION
Toner falling from the1. Clean the cleaning unit.
cleaning unit.2. Replace the first seal and/or side seals.
NOTES: (1) When adhearing the first seal, make sure it is flat and not wavy.
(2) When installing side seals, make sure they are aligned correct-
ly. Press firmly at the points indicated in the figure.
CAUTION: After doing above action do not forget to dust the cleaning blade,
cleaning seal, and cleaning side seals with setting powder.
Cleaning Blade
Press