14VT-N10T(S)
REMOVING AND INSTALLING THE CAS-Notes:
SETTE HOUSING1. When fitting the S/E sensor holder to the cassette
Y Removalcontroller frame L/R, take care.
1. In the cassette eject mode, remove the cassette.2. Misengagement of teeth of casecon drive gear and
2. Unplug the power cord.drive angle gear causes malfunction. (The cassette
3. Remove in the following numerical order.cannot be set, load and ejection are repeated).
a) Remove two screws 1.3. In the case when you use the magnet screw driver,
b) Slide and pull up the cassette housing control.never approach the magnet driver to the A/C head, FE
head, and drum.
4. When installing or removing, take care so that the
1
cassette housing control and tool do not contact the
guide pin or drum.
5. After installing the cassette housing control once per-
form cassette loading operation.
TO RUN A TAPE WITHOUT THE CASSETTE
HOUSING CONTROL ASSEMBLY
1. Short-circuit TP7701 and TP7702.
2. Plug in the power cord.
3. Turn on the power.
4. Open the lid of a cassette tape by hand.
5. Hold the lid with two pieces of vinyl tape.
6. Set the cassette tape in the mechanism chassis.
7. Stabilize the cassette tape with a weight (500g) to
prevent floating.
8. Perform running test.
Figure 1-1.
Y Reassembly500g
1. Before installing the cassette housing control, short-
circuit TP7701 and TP7702 provided at the left of the
main PWB, prug in the power cord. The casecon drive
Weight to prevent
gear turns and stops when the positioning mark ap-Mechanism chassis
float (500g)
pears. Engage two teeth of casecon drive gear with
the three teeth of casecon drive angle gear, and set on
the mechanism chassis as shown below.Figure 1-3.
Notes:
Casecon1. The weight should not be more than 500g.
drive gear
2. Take care not to damage the tape when the Cassette
Casecon drive
angle gearis set in the mechanism shassis or taken out of it
because the supply/take-up poles are shifted foward
the tape loading direction in the EJECT position.
Figure 1-2.
2. Install in the reverse order of removal.
21 |