6550-T3N/U3N
DIAGNOSIS
FailurePower LED
HV/+B FailureBlink Amber (On 0.5 sec, Off 0.5 sec)
H Stop or V Stop (Included S-Cap)Blink Amber (On 0.5 sec, Off 0.5 sec)
ABL FailureBlink Amber (On 0.5 sec, Off 1.5 sec)
Aging/Self-TestBlink Amber (On 0.5 sec, Off 0.5 sec) .... Blink Green (On 0.5 sec, Off 0.5 sec)
TIMING SPECIFICATION
PRIMARY MODEPRIMARY
MODE AT PRODUCTIONMODE 1MODE 2MODE 3MODE 4MODE 5MODE 6MODE 7MODE 8MODE 9MODE 10
RESOLUTION640 X 480640 X 480640 X 480800 X 600800 X 6001024 X 7681024 X 768 1280 X 10241280 X 1024 1600 X 1200
CLOCK25.175 MHz31.500 MHz36.000 MHz49.500 MHz 56.250 MHz78.750 MHz94.500 MHz 135.000 MHz157.500 MHz 202.500 MHz
N HORIZONTAL N
H-FREQ31.469 kHz37.500 kHz43.269 kHz46.875 kHz53.674 kHz60.023 kHz68.677 kHz79.976 kHz91.146 kHz93.750 kHz
usecusecusecusecusecusecusecusecusecusec
H. TOTAL31.77826.66723.11121.33318.63116.66014.56112.50410.97110.667
H. BLK6.3566.3495.3335.1724.4093.6573.7253.0222.8442.765
H. FP0.6360.5081.5560.3230.5690.2030.5080.1190.4060.316
H. SYNC3.8132.0321.5561.6161.1381.2191.0161.0671.0160.948
H. BP1.9073.8102.2223.2322.7022.2352.2011.8371.4221.501
H. ACTIV25.42220.31717.77816.16214.22213.00310.8369.4818.1277.901
N VERTICAL N
V. FREQ(HZ)59.940 Hz75.000 Hz85.008 Hz75.000 Hz85.061 Hz75.029 Hz84.997 Hz75.025 Hz85.024 Hz75.000 Hz
lineslineslineslineslineslineslineslineslineslines
V. TOTAL525500509625631800808106610721250
V. BLK45202925313240424850
V. FP10111111111
V. SYNC2333333333
V. BP33162521272836384446
V. ACTIV480480480600600768768102410241200
N SYNC N
INT(G)NONONONONONONONONONO
EXT(H/V)/POLARITYYES -/-YES -/-YES +/+YES +/+YES +/+YES +/+YES +/+YES +/+YES +/+YES +/+
EXT(CS)/POLARITYNONONONONONONONONONO
INT/NON INTNON INTNON INTNON INTNON INTNON INTNON INTNON INTNON INTNON INTNON INT
99.5.18 VER.
Notes
Power Saving FunctionY When your computer is in a power saving mode, MONITOR IS
IN POWER SAVE MODE appears on the screen if you press any
This monitor meets the power-saving guidelines set bybutton on the monitor (page 15). After a few seconds, the
VESA and ENERGY STAR, as well as the more stringentmonitor enters the power saving mode again. Once the
NUTEK .horizontal and vertical sync signals are detected, the monitor
automatically resumes its normal operation mode.
If the monitor is connected to a computer or video graphics
Y The power management feature is invoked when the computer
board that is VESA DPMS (Display Power Management
recognizes that you have not used your mouse or keyboard for a
Signaling) compliant, the monitor will automatically reduceuser-definable period of time.
power consumption in three stages as shown below.Y IBM recommends that you switch off your monitor at the end of
each working day, or whenever you expect to leave it unused for
long periods during the day.
Power consumptionScreenHorizontalVerticalPowerRecovery timeu indicator
modesync signalsync signalconsumption
1Normal operationactivepresentpresentL 130 WNGreen
2Standby (1st mode)blankabsentpresentL 15 WApprox. 5 sec.Green and orange
alternate
3Suspend (2nd mode)blankpresentabsentL 15 WApprox. 5 sec.Green and orange
(sleep)*alternate
4Active-off (3rd mode)blankabsentabsentL 3 WApprox. 15 sec.Orange
(deep sleep)*
5Power-offNNNL 0.5 WNOff
* OSleep� and Odeep sleep� are power saving modes defined by the Environmental Protection Agency.
� 2 � |