SECTION 3
TEST MODE
[MC Cold Reset][Change-over of AM Tuner Step between 9kHz and 10kHz]
? A step of AM channels can be changed over between 9kHz and
? The cold reset clears all data including preset data stored in the
10kHz.
RAM to initial conditions. Execute this mode when returning
Procedure:
the set to the customer.
1. Press POWER button to turn the set ON.
Procedure:
2. Select the function OTUNER�, and press TUNER/BAND
1. Press three buttons GROOVE , ENTER/NEXT , and
button to select the BAND OAM�.
DISC 1 simultaneously.
2. The fluorescent indicator tube becomes blank instantaneously3. Press POWER b,utton to turn the set OFF.
and the set is reset.4. Press ENTER/NEXT and POWER buttons simultaneously,
and the display of fluorescent indicator tube changes to OAM
9k STEP� or OAM 10k STEP�, and thus the channel step is
[CD Delivery Mode]
changed over.
? This mode moves the pickup to the position durable to vibra-
tion. Use this mode when returning the set to the customer after
[LED and Fluorescent Indicator Tube All Lit, Key Check
repair.
Procedure:Mode]
1. Press POWER button to turn the set ON.Procedure:
2. Press PLAY MODE button and POWER button simulta-1. Press three buttons GROOVE , ENTER/NEXT , and DISC 3
neously.simultaneously.
3. A message OLOCK� is displayed on the fluorescent indicator2. LEDs and fluorescent indicator tube are all turned on.
tube, and the CD delivery mode is set.Press DISC 2 button, and the key check mode is activated.
3. In the key check mode, the fluorescent indicator tube displays
OK 1 V0 J0�. Each time a button is pressed, OK�value in-
[MC Hot Reset]
creases. However, once a button is pressed, it is no longer taken
? This mode resets the set with the preset data kept stored in the
into account.
memory. The hot reset mode functions same as if the power
OJ� Value increases like 1, 2, 3 ... if rotating JOG knob in O+�
cord is plugged in and out.
direction, or it decreases like 0, 9, 8 ... if rotating in O�� direc-
Procedure:
tion.
1. Press three buttons GROOVE , ENTER/NEXT , and
OV� Value increases like 1, 2, 3 ... if rotating VOLUME knob
DISC 2 simultaneously.
in O+� direction, or it decreases like 0, 9, 8 ... if rotating in O�
2. The fluorescent indicator tube becomes blank instantaneously,
� direction.
and the set is reset.
4. To exit from this mode, press three buttons in the same man-
ner as step 1, or disconnect the power cord.
[Sled Servo Mode]
? This mode can run the CD sled motor freely. Use this mode, for
instance, when cleaning the pickup.
Procedure:
1. Select the function OCD�.
2. Press three buttons GROOVE , ENTER/NEXT , and
FLASH simultaneously.
3. The Sled Servo mode is selected, if OCD� is blanking on the
fluorescent indicator tube.
4. With the CD in stop status,) button in CD section press
to move the pickup to outside tr0 button to insideack, or
track.
5. To exit from this mode, perform as follows:
1) Move the pickup to the most inside track.
2) Press three buttons in the same manner as step 2.
Note:
? Always move the pickup to most inside track when exiting from
this mode. Otherwise, a disc will not be unloaded.
? Do not run the sled motor excessively, otherwise the gear can
be chipped.
[Change-over of FUNCTION Name]
? The FUNCTION name of external input terminal can be changed
over to VIDEO or MD. With the FUNCTION selected to OMD�,
about 5dB mute is applied to the input gain.
Procedure:
1. Press POWER button to turn the set OFF.
2. Press POWER button together with FUNCTION button, and
the power is turned on, the display of fluorescent indicator
tube changes to OMD� or OVIDEO� instantaneously, and thus
the FUNCTION is changed over.
� 30 � |