2-15. Cleaning of Optical Connector
2-16. Note on Replacement of Lithium Battery
2. When the turn stops, pull out the remover in the2-16. Note on Replacement of Lithium
straight line forcedly.Battery
n
The alignment sleeve can be removed/reinstalled withThe unit has a lithium battery on the IF-569 board. If the
the sleeve itself attached to the tip of the remover.lithium battery runs down, adjustment data and so on set
Great care should be taken so as not to lose or damageby MSU, RCP or using the setup menu are reset to their
the alignment sleeve.factory-set values. And the scene file is cleared. The
(Alignment sleeve: Sony P/N 9-980-074-01)lithium battery running down, setup the unit again as
necessary.
Alignment sleeve
BT1/IF-569 board: CR2025 (commercially available)
In replacing, ensure that the battery is installed with O+�
and O_� poles connected to the correct terminals. An
improper connection may cause an explosion or leakage of
fluid.
3. Clean the tip of the white optical contacts by a cotton
swab moistened with alcohol.
Optical contacts (white)
4. Insert the remover with the alignment sleeve attached
to its tip, and push it until it clicks.
5. Rotate the remover counterclockwise to install the
alignment sleeve, and extract the remover.
Optical connector cable
After replacing the optical connector of the camera or
HDCU, or replacing the SDI-10/RX-28 board, clean the tip
of the white optical contact of the optical connector cable
by a cotton swab moistened with alcohol.
Optical contact (white)
2-22 (E)HDC-700A |