BM 1619929600 11/02 11/18/02 8:18 AM Page 13
Maintenance
Servicetools with gears be regreased with a special
NO USER SERVICEABLEgear lubricant yearly.
!WARNING
PARTS INSIDE. PreventiveD.C. MOTORS
maintenance performed by unauthorizedThe motor in your tool has been engineered
personnel may result in misplacing offor many hours of dependable service. To
internal wires and components whichmaintain peak efficiency of the motor, we
could cause serious hazard. We recom-recommend it be examined every six
mend that all tool service be performed by amonths. Only a genuine Bosch replacement
Bosch Factory Service Center or Authorizedmotor specially designed for your tool should
Bosch Service Station. SERVICEMEN:be used.
Disconnect tool and/or charger from power
source before servicing.Cleaning
BATTERIESTo avoid accidents,
!WARNING
Be alert for battery packs that are nearingalways disconnect the
their end of life. Battery packs typically lasttool and/or charger from the power
from 500 to 1000 charges. If you noticesupply before cleaning. The tool may be
decreased tool performance or significantlycleaned most effectively with compressed
shorter running time between charges then itdry air. Always wear safety goggles when
is time to replace the battery pack. Failurecleaning tools with compressed air.
to do so can cause the tool to operate
Ventilation openings and switch levers must
improperly or damage the charger.
be kept clean and free of foreign matter. Do
Long term battery storage should be innot attempt to clean by inserting pointed
the discharged state. Battery packs last
objects through opening.
longer and re-charge better when they are
Certain cleaning agents
stored discharged. Remember to fully re-!CAUTION
and solvents damage
charge battery packs before using after
plastic parts. Some of these are: gasoline,
prolonged storage.
carbon tetrachloride, chlorinated cleaning
TOOL LUBRICATIONsolvents, ammonia and household
Your Bosch tool has been properly lubricateddetergents that contain ammonia.
and is ready for use. It is recommended that
Accessories
If an extension cord isRECOMMENDED SIZES OF EXTENSION CORDS
!WARNING
necessary, a cord with120 VOLT ALTERNATING CURRENT TOOLS
adequate size conductors that is capableCord Size in A.W.G.Wire Sizes in mm2
ToolOs
of carrying the current necessary for yourAmpere
tool must be used. This will preventRatingCord Length in FeetCord Length in Meters
excessive voltage drop, loss of power or2550 100 15015 30 60 120
overheating. Grounded tools must use 3-3-618161614.75 .75 1.5 2.5
wire extension cords that have 3-prong6-818161412.75 1.0 2.5 4.0
plugs and receptacles.8-1018161412.75 1.0 2.5 4.0
10-12161614121.0 2.5 4.0 N
NOTE: The smaller the gauge number, the
heavier the cord.12-161412NNN N NN
360u Auxiliary Handle*(* = standard equipment)
Depth Gauge*(** = optional accessories)
Carrying Case*
3-Jaw Chuck**
Straight Chuck SDS Adaptor**
-13- |