BM 2610908996 6-04 6/21/04 4:47 PM Page 22
Maintenance
Serviceshould be replaced at Bosch Factory Service
Preventive maintenanceCenter or Authorized Bosch Service Station.
!WARNING
performed by unauthorizedBearings which become noisy (due to heavy
personnel may result in misplacing ofload or very abrasive material cutting) should
internal wires and components whichbe replaced at once to avoid overheating or
could cause serious hazard. Wemotor failure.
recommend that all tool service be performed
by a Bosch Factory Service Center or Autho-
Cleaning
rized Bosch Service Station.
To avoid accidents always
!WARNING
TOOL LUBRICATIONdisconnect the tool from
Your Bosch tool has been properly lubricatedthe power supply before cleaning or
and is ready to use. It is recommended thatperforming any maintenance. The tool may
tools with gears be regreased with a specialbe cleaned most effectively with compressed
gear lubricant at every brush change.dry air. Always wear safety goggles when
cleaning tools with compressed air.
CARBON BRUSHES
The brushes and commutator in your toolVentilation openings and switch levers must
have been engineered for many hours ofbe kept clean and free of foreign matter. Do
dependable service. To maintain peaknot attempt to clean by inserting pointed
efficiency of the motor, we recommend everyobjects through openings.
two to six months the brushes be examined.Certain cleaning agents
!CAUTION
Only genuine Bosch replacement brushesand solvents damage
specially designed for your tool should beplastic parts. Some of these are: gasoline,
used.carbon tetrachloride, chlorinated cleaning
solvents, ammonia and household detergents
BEARINGS
that contain ammonia.
After about 300-400 hours of operation, or at
every second brush change, the bearings
Accessories
If an extension cord isRECOMMENDED SIZES OF EXTENSION CORDS
!WARNING
necessary, a cord with120 VOLT ALTERNATING CURRENT TOOLS
adequate size conductors that is capable2
ToolOs Cord Size in A.W.G.Wire Sizes in mm
of carrying the current necessary for your
Ampere
tool must be used. This will preventRatingCord Length in FeetCord Length in Meters
excessive voltage drop, loss of power or2550 100 15015 30 60 120
overheating. Grounded tools must use 3-wire3-6181616140.75 0.75 1.5 2.5
extension cords that have 3-prong plugs and6-8181614120.75 1.0 2.5 4.0
receptacles.8-10181614120.75 1.0 2.5 4.0
NOTE: The smaller the gauge number, the10-12161614121.0 2.5 4.0 N
12-161412NNN N NN
heavier the cord.
1/4� Collet Chuck *Edge-Forming Dust Extraction Hood **
1/2� Collet Chuck *Fine Adjustment Control Extension **
16 mm Shaft Wrench *Undertable Base with Fine Adjustment
24 mm Collet Nut Wrench *Control Extension **
3/8� Collet Chuck **Router Tables **
8 mm Collet Chuck **Quick-Release Templet Guides **
Deluxe Router Guide **Adapter for Standard-Style Templet Guides **
Centering Cone **
Carry Case (Std with 1617K, 1617EVSK, *= standard equipment
1617PK, 1617EVSPK only)**= optional accessories
Dust Extraction Hoods **
-22- |