2.12.1 MAGIC FOCUS Character Set-UpTABLE 1. - DCU PARAMETER
This instruction should be applied when a new DCU
is being replaced.1080i
ParameterNormalThrough
Adjustment Preparation
ADJ. DISP77Y
(1) Receive NTSC RF or video signal.
SEL. STAT00Y
(2) With Power off, PRESS and HOLD the SERVICE
ONLY button on CONVER/FOCUS PWB, then pressDEMO WAIT2FY
the Power On/Off, when picture appeares releaseINT STEP 102Y
SERVICE ONLY switch. (Internal crosshatch isINT A DLY0AY
displayed without conv. correction data.)INT C DLYFAY
Adjustment ProcedureINT BAR1CY
MGF STEP 1 00YNORMAL MODE
MGF A DLY0AY
(1) Press FREEZE key on R/C. (One additional line
MGF C DLYFAY
appears near the top and near the bottom.)
MGF BAR0EY
(2) Press PIPCH key, then ADJ. PARAMETER mode is
SENSOR CK00Y
displayed as following.
SENSOR 0FFY
(3) Press F or E key to change the ADJ. DISP. data.
SENSOR 100Y
SENSOR 2FFY
SENSOR 301Y
SENSOR 4FFYADJ. PARAMETER
ROM WRITE?
SENSOR 506YR ADJ. DISP. : 77
SENSOR 6FFY
SEL. STAT. : 00SENSOR 707Y
DEMO.WAIT : 2fAD LEVEL03Y
E. DISPLAY00Y
ADJ. TIMS60Y
AD LEVEL05Y
(4) Press CURSOR H to access DCU parameter.
AD NOISE80Y
Change the data as shown on Table 1, DCU
Parameter.PHASE MOT60Y
H. BLK-RV0603
H. BLK-GV01Y
H. BLK-BV0603
H. BLK-H00Y
PON DELAY0cY
IR-CODE00Y
INITIAL 509EY
MGF 5096Y
9 POINT 50FEY
STAT 50FEY
DYNA 509FY
46 |