Code No.Setting (The default is Highlighted ).
<ADF FD Zoom adjustment>
Adjust the zoom ratio in the FD direction on the ADF side.
It is used when the machine is set up, the PH Unit or Scanner Drive
--7Cables have been replaced, or the Scanner has been removed.
Setting87.............................. 100 ........................113
Description (%) 9.48............................100 .....................105.2
<ADF CD Registration adjustment>
Adjust registration in the CD direction on the ADF side.
It is used when the machine is set up, or the PH Unit or CCD Unit has
--8been replaced.
Setting20 ..............................100........................ 180
Description (mm) -8.0..............................0......................... +8.0
<ADF FD Registration adjustment>
Adjust registration in the FD direction on the ADF side.
It is used when the PH Unit or Scanner Drive Cables have been
--9replaced, or the Scanner has been removed.
Setting50 ..............................100........................ 150
Description (mm) -5.................................0............................ +5
<ATDC Sensor Gain Manual adjustment>
Adjust the ATDC Sensor voltage.
It is used when an IU of another machine is to be used or the T/C con-
trol voltage is to be changed.
-10Setting123............................ 155 ........................186
Description (V) 5.39...........................6.79.......................8.15
= The value, to which F-8 (ATDC Sensor Automatic Adjustment) has
been adjusted, is to be the setting value.
Be sure to set to ?1? whenever Memory Clear has been effected on
the 18-cpm machine.
-11
Setting01
<Test Print>
This function is used to produce a test print, when a check is made
after a setting value of an Adjust function has been changed and on
-12image.
<Procedure>
1. Select the paper source (Bypass Tray cannot be selected).
2. Press the START to let the machine produce a test print.
-20= This test is for factory adjustment only and should NOT be used.