A malfunction may be caused by only a minor fault that you can re
tify yourself using the following instructions.
Please check whether the pilot lights come on, the refrigerating unit
operates, and the internal temperature is being maintained. Do not
perform any other work on the appliance if the following information
does not provide assistance in your specific case.
Warning! Repairs to refrigerators/freezers may only be performed by
competent service engineers. Improper repairs can give rise to signifi-
cant hazards for the user. If your appliance needs repairing, please
contact your specialist dealer or our Customer Service.
If the freezing mechanism has stopped working, the reserve in the
cold accumulator and in the deep-frozen food itself, if the freezer is
full, will be sufficient for about 27 hours, or about 18 hours if there is
no cold accumulator.
MalfunctionPossible CauseRemedy
Appliance is not switched
Switch on the appliance.
on.
Mains plug is not plugged
Insert mains plug.
Appliance does not work,in or is loose.
no pilot light isFuse has blown or isCheck fuse, replace if
illuminated.defectivenecessary.
Mains malfunctions are to
Socket is defective.be corrected by an
electrician.
Green light does not light
up, yellow light lights upPlease inform your
Green light faulty.
when the fast freeze func-customer service.
tion is activated.
Yellow light does not light
up, when the fast freezePlease inform your
Yellow light faulty.
function is activated,customer service.
appliance is on.
Turn the temperature
Temperature is set too
Appliance cools too much.regulator to a warmer set-
cold.
ting temporaily.