Changes fan speed setting manually. Press the buttonContinue cleaning the air cleaner as follows (stage 3)
to switch between the different fan speeds.(e) Vacuum the grille at the top of the space. (f) Lift the grille
Turns the air cleaner on and off.using the handle. (g) Remove the wire holder carefully with both
Activates/deactivates the button lock. Press thehands keeping it level and upright. (h) Vacuum the inside of the
button for longer than two seconds to activate thecleaner, including the lower grille, with the brush or crevice
button lock. The indicator lamp will flash first and thennozzle. If necessary, use a damp cloth with mild detergent.
remain on while the lock is activated. The same pro-(i) Carefully refit the wire holder using both hands and close
cedure applies for deactivating the button lock.the grille. (If the wire is broken please refer to the troubleshoo-
ting section.) (j) Replace the main filter. Make sure the guides
Resets the air cleaner after changing the filter or after
a fault in the air cleaner. Press the button for longerare properly set in the grooves when you put the filter back.
(k) Replace the cover.
than two seconds. The indicator lamp will flash first
and then go out once the cleaner has been reset.Resetting the air cleaner (stage 4)*
Functions (only models with automatic programmes andPress the reset button (4) after cleaning or replacement. The
functions)warning lamp goes out to indicate that the air cleaner has
been reset. The air cleaner is reset automatically on models
AThis program adjusts the fan speed according to the
that do not have a warning lamp.
degree of pollutants in the room.
BThis program adjusts the fan speed according to theFilter cleaning intervals
noise level in the room. The air cleaner will operate at
Depending on the level of ambient contamination, we recom-
the highest possible fan speed without increasing themend that you follow the above procedure every two months or
noise level in the room.when the indicator on the display lights up. The main filter may
CThis function can be used, for example, when comingneed cleaning more frequently if dust is visible on the upper filter
home after a dayOs work to quickly clean the roomsurface.
from pollutants. This programme has three different
Replace the main filter once a year or more frequently if
modes.necessary, or when the indicator on the display lights up.
The air cleaner automatically operates at setting 3.
After 15 minutes, it will automatically drop to setting 1.When using the carbon filter, replace every three to six months
or sooner if you are no longer able to detect a reduction in gases
The air cleaner will be turned off after two hours. The
and smells.
fan speed setting is selected manually. The setting
can be changed during the preset operating duration.
Troubleshooting air cleaner problems when fault
The air cleaner will be turned off after nine hours.
indicator on display comes on or the blue indicator
Fan speed setting as above (2h).
lamp changes colour to red (depending on model)
DIndicates the degree of pollutants in the room. Adjust
to suitable fan speed setting or use auto program .Y A break in the corona wire (stage 1) is shown in figure (g)
and is used as a reference in the paragraph ŤContinue
High degree of pollutants.
Medium degree of pollutants.cleaning the air cleaner as followsŽ.
Low degree of pollutants.Change the wire as instructed below. Press the reset button
(4). If the fault indicator comes on again after a short period,
EIndicates current fan speed setting.
proceed with the next stage.
FThis symbol shows that the machine is operating
Changing corona wire - Remove the broken wire. Carefully
optimally and is supplying clean air. The symbol willreplace the new wire as follows: Secure one end of the wire into
be extinguished and the respective fault indicator
the groove. Bend the wire holder slightly and attach the other
lamp ( ) will come on when itOs time to change
end.
the filters or an air cleaner fault has occurred.
Y Additional cleaning(stage 2)
GIndicates that the filters should be cleaned according
to the cleaning schedule below.Clean the filter and the ionization chamber inside the air
HIndicates a fault in the air cleaner. Refer to the instruc-cleaner according to the maintenance instructions. Get in
touch with your service station if the fault indicator comes on
tions under OAir cleaning problems�.
again after a short period.
IWith the button lock activated you can press all the
buttons without anything happening, which can beTroubleshooting
used around children.
Y If the fan does not operate, (ie. if you cannot sense a weak air
current), check that the power cable is undamaged and that it is
Cleaning and maintenance
connected to the power supply. Check that the cover and filters
Always disconnect the power supply prior to cleaning the unit.
are correctly set. If the fan still does not start, take your air clea-
Pre-filterner to an authorised Lux service station for inspection.
(a) Open the access door (9). (b) Take out the filters one at aY If a continuous crackling sound can be heard from the main
time and vacuum them. Use the brush accessory to avoidfilter, lift up the filter and turn it 180°. If this does not remedy
damaging the filters. After cleaning filters insert and close thethe problem, take the unit for service. (A soft hissing coming
door. The pre-filters do not need to be replaced. Follow thisfrom the filter is normal, especially when new.)
procedure every two months or more often for sensitive people,Y If the indicator lamp (15) does not light up though the fan is
e.g. when vacuuming your home.
operating, take the unit for service. (This applies only to air
Main filtercleaners without automatic functions.)
(c) Press the button (13) and lift off the cover. (d) Take out and
vacuum the main filter first with a vacuum cleaner fitted with a
brush nozzle.
3 |