Part 1 - INSTALLATION INSTRUCTIONS
1 - GENERAL INFORMATION
This canopy hood is designed to be fitted into cabinets or chimney cooker hoods, placed
above a hotplate. It can be used either in the extraction mode (ducted to the outside) or in the
recirculation mode (internal recycling). Before starting the installation, consideration should
be given to the difficulties to be found during installation. The installation work must be
undertaken by a qualified and competent person in conformity to the rules concerning the
evacuation of contaminated air. The manufacturer disclaims all liability for any damage or
injury caused as a result of not following the instructions for installation contained in the
following text.
2 - SAFETY WARNINGS
2.1 - When used in the extraction mode, the cooker hood ducting must not be connected to a
flue which is used for exhausting fumes from appliances supplied with energy other than
electric, such as a central heating flue or water heating flue.
2.2 - Before connecting to the mains supply ensure that the mains voltage corresponds with
the voltage on the rating plate inside the hood.
2.3 - Connect the cooker hood to the mains via a bipolar switch which has 3mm clearance
between the contacts.
2.4 - The device does not require earthing, as it is double-insulated.
2.5 - When installed, the hood must be positioned at least 65 cm above the hotplate.
2.6 - Never do flambŽ cooking under this cooker hood.
2.7 - Never leave frying pans unattended during use as overheated fat and oil may catch fire.
2.8 - Before carrying out any kind of maintenance or cleaning, disconnect the hood from the
mains supply.
2.9 - If the room where the cooker hood is to be used contains a fuel burning appliance such
as a central heating boiler then this must be of the room sealed or balanced flue type. If
other types of flue or appliance are fitted, ensure that there is an adequate supply of air
into the room. When the cooker hood is used in conjunction with appliances supplied
with energy other than electric, the negative pressure in the room must not exceed 0,04
mbar to prevent fumes being drawn back into the room by the cooker hood.
3 - INSTALLATION
The following scheme has to be observed:
3.1 - Installation of the built-in group
3.2 - Set the hood for recirculation or evacuation
3.3 - Connect the hood to the mains supply and ensure that it works properly
3.1 - Installation of the fitted group
1 - Make a rectangular opening in the base of the overhead cupboard or hood, leaving a
minimum of 13 mm from the outer edges according to the dimensions indicated in the table.
9 |