Flue assembly - Mounting the hood body
Y Position the upper chimney section and fix the
upper part to the frame using the 2 screws 12c
provided.
Y Fit the lower chimney section onto the frame,
holding it in place until the hood body has been
fixed in place.
Recirculation version
Y Make sure that the outlet of the extension piece8b
14.1 is horizontally and vertically aligned with
the chimney outlet.
Y If this is not the case, remove the lower chimney
section and adjust the position by cutting the
hood body extension 14 along one of the thinner
section channels denoting the pre-fixed lenghts,
then reassemble as described previously.
12f
Before fixing the hood body to the frame:
Y Remove the grease filters from the hood body;
Y Remove any activated charcoal filters.
Y From below, use the 4 screws 12f provided to
fix the hood body to the frame.
Y For the recirculation version, locate the
directional grill 8 in its housing. Ensure that it
is inserted correctly in connector 15.
ELECTRICAL CONNECTION
Y Connect the hood to the mains through a two-
pole switch having a contact gap of at least 3
mm.
Y Take off the upper protection bracket by
unscrewing the screws.
Y Connect the control connector Cmd .
Y Reassemble the protection bracket.
Y Take off the bracket which is opposite to the
previous one by unscrewing the screws.
Y Connect the spotlights connector L.
Y Reassemble the protection bracket.Cmd
Y For the recirculation version, fit the activated
carbon odour filter.
Y Replace the grease filters.
L