6. AUTO OFF LIST
CodeAuto-Off condition
04Failure of the pinch-roller solenoid or reel brake solenoid drive circuit has been detected.
08Failure of the cleaning solenoid drive circuit has been detected.
Where the radius of the tape winding is the minimum, the reel is rotating at the speed of more than
0B
150 times normal playback speed.
When the tape is running in the reel drive mode, the tension sensor voltage continues to be less
0B
than 0.3 V or more than 4.7 V for more than 5 seconds.
0BThe take-up reel has rotated more than one turn in the direction opposite to the tape running.
When the capstan has driven the tape by 3 cm, the number of FG counts of the take-up reel is less
0C
than the specified value (before detecting the radius of the tape winding).
In ? one time playback speed, when the amount of tape transport either on the take-up reel or
supply reel has reached 3 cm, the difference in the amount of tape transport between the two reels
0Cis more than 2 cm (after detecting the radius of the tape winding).
When the tape is running, FG output of the take-up reel is not counted for 5 seconds (irrelevant to
tape radius detection).
Where the radius of the tape winding is the minimum, the reel rotates at the speed of more than 150
0D
times normal playback speed for more than 2 seconds.
When the tape is running in the capstan mode, the tension sensor voltage continues to be less than
0D
0.3 V for 5 seconds.
0DWhile the capstan motor is rotating, the FG output is not detected for more than 5 seconds.
While the cylinder motor is rotating, the FG output is not detected for more than one second.
0E
The PG output is not detected for more than 5 seconds.
While the cylinder is rotating, the period of the PG pulses continues to be less than 3 msec for 2
0E
seconds.
0FTape loading does not finish within 10 seconds.
Tape loading error: if tape loading is locked after the half loading, the loading is retried three times
0F
and the loading is still locked at the fourth retry.
0FTape unloading does not finish within 10 seconds.
From the start of tape loading to the half loading, the tension sensor voltage continues to be more
than 1.5 V for 40 msec.
0F
When the tape is running in FF/REW after the white tape has been detected at the half loading, the
output of the take-up reel FG counts more than five times the output from the white tape length.
0FThe tape is not wound up during unloading.
0FThe tape start or tape end processing does not finish even after 10 seconds.