Parts and their functions
$ Camera control unit front panel
CABLETALLY/CALL
OPENSHORTALARM
87
FUSEFUSE:
125V 5A250V 5A
9
56
;<=
LEVELPGM 1PGM
34
OFF
MAINHEAD POWERPGM 2
SYSTEM>PUSH
PRIVATE
MIC?
ON
OFF
PTT
12@Camera Control Unit
1 CCU power switch [MAIN]8 Camera cable open alarm LED [CABLE / OPEN]
This is the power switch of the camera control unitLighted: The cable between the CCU and camera has
(CCU). The CCU, ROP and other units will not operatebeen disconnected.
unless this switch is set to ON.Off:Normal
Up:ON
Down: OFF9 Camera cable short-circuit alarm LED
[CABLE / SHORT]
2 Camera power switch [HEAD POWER]Lighted: The cable between the CCU and the camera has
This switch supplies power to the camera. However, ifshort-circuited.
the ROP has been connected, power is supplied to theOff:Normal
camera only when this switch and the camera power
switch on the TOP are both set to ON.: TALLY indicator/CALL switch [TALLY/CALL]
Up:ONThis indicator lights when the R/G tally signal is input. It
Down: OFFis also a CALL switch for calling the camera, ROP and
MSU.
3 CCU power ON LED
Lighted: The CCU power is ON.; INCOM volume control [LEVEL]
Off:The CCU power is OFF.This is used to adjust the standby INCOM volume.
4 Camera power ON LED< INCOM PGM selector switch
Lighted: This indicates that power is being supplied fromThis is used to select the PGM input signals which are to
the CCU to the camera.be mixed with the standby INCOM.
Off:This indicates that power is not being supplied
from the CCU to the camera.= INCOM PGM level control [PGM]
Even if the camera power switch is ON, this LED remainsThis is used to select the level of the PGM signals which
off if no power is supplied to the camera.are to be mixed with the standby INCOM.
This is due to one of the following reasons: 1 the supply
of power to the camera has been turned off by the ROP,> INCOM selector switch
2 one of the optical fiber cables has been disconnectedThis is used to select the call party of the standby
or 3 something is wrong with the camera, and the powerINCOM.
supply was turned off.PRIVATE: For making private calls to the camera.
COMM:For connecting the standby INCOM with the
5 CCU power fusesystem INCOM.
This is the CCU main power fuse.
? INCOM MIC selector switch [MIC]
6 Camera head power fuseON:The INCOM microphone is set to ON.
This is the camera head power supply fuse.OFF: The INCOM microphone is set to OFF.
PTTN: The INCOM microphone is set to ON only while
7 Alarm LED [ALARM]the INCOM MIC selector switch is held down.
Lighted: This LED indicates that the CCUOs fan has
stopped and that something is wrong with the@ Standby INCOM jack
power supply.This is connected to INCOM 1 line, and it enables calls to
Off:Normal be made to the cameraOs INCOM 1 line.
If the LED remains lighted, turn off the main power andEven when the camera power is OFF, calls can still be
have the unit repaired.made to the cameraOs INCOM 1 line.
4 |