Contact Us
Privacy Notice
Shipping & Returns
Search for Manual:  
 
Search
 
Categories
 ACEC
 ACER
 AEG
 AIKO
 AIWA
 AKAI
 ALBA
 ALFATEC
 ALINCO
 ALNO
 ALPINE
 AMSTRAD
 AOC
 APPLE
 ARTHUR MARTIN ELECTROLUX
 ATAG
 ATLAS-ELECTROLUX
 BANG&OLUFSEN
 BARCO
 BAUKNECHT
 BECKER
 BEKO
 BELINEA
 BLAUPUNKT
 BOSCH
 BOSS
 BRANDT
 BRAUN
 BROTHER
 BUSH
 CANON
 CASIO
 CASTOR
 CLARION
 CLATRONIC
 COMMODORE
 COMPAQ
 CORBERO
 CRATE
 CROSSLEE
 CROWN
 CTX
 CURTISS
 DAEWOO
 DECCA
 DENON
 DIORA
 DOMETIC
 DUAL
 ELECTROLUX
 ELEKTRA
 ELEKTRA BREGENZ
 ELEKTRO HELIOS
 ELITE
 ERICSSON
 ESCOM
 FAURE
 FENDER
 FERGUSON
 FINLUX
 FISHER
 FLYMO
 FRIGIDAIRE
 FUNAI
 GELHARD
 GEMINI
 GOODMANS
 GRAETZ
 GRANADA
 GRUNDIG
 HAMEG
 HANSEATIC
 HARMAN
 HARMAN KARDON
 HEWLETT-PACKARD
 HITACHI
 HUSQVARNA
 HYUNDAI
 IAT
 IGNIS
 INFINITY
 INTEGRA
 ITT
 JBL
 JOHN LEWIS
 JUNO-ELECTROLUX
 JVC
 KAWAI
 KENWOOD
 KODAK
 KOERTING
 KORG
 KUPPERSBUSCH
 LADEN
 LG-GOLDSTAR
 LLOYDS
 LOEWE
 LUX
 LUXMAN
 LUXOR
 M-AUDIO
 MACKIE
 MARANTZ
 MARYNEN
 MATSUI
 MATURA
 MAX-FIRE
 MCCULLOCH
 MEDION
 METZ
 MICROVITEC
 MIELE
 MINOLTA
 MITAC
 MITSUBISHI
 MOFFAT
 MOTOROLA
 MTC
 NAD
 NAKAMICHI
 NEC
 NN
 NOKIA
 NORDMENDE
 NUMARK
 OKI
 ONKYO
 OPTIQUEST
 ORION
 OTHERS
 PACE
 PALLADIUM
 PANASONIC
 PARKINSON COWAN
 PARTNER
 PEACOCK
 PERICOM
 PHILIPS
 PIONEER
 POLAR
 POLAROID
 PRIVILEG
 PROGRESS
 QUELLE
 REVOX
 REX-ELECTROLUX
 RFT
 RICOH
 ROADSTAR
 ROLAND
 ROSENLEW
 ROTEL
 SABA
 SALORA
 SAMSON
 SAMSUNG
 SANGEAN
 SANSUI
 SANYO
 SCHNEIDER
 SEG
 SELECO
 SENNHEISER
 SEPPELFRICKE
 SHARP
 SHERWOOD
 SHURE
 SIEMENS
 SILENTIC
 SONY
 TANDBERG
 TAXAN
 TEAC
 TEC
 TECHNICS
 TELEFUNKEN
 TENSAI
 THERMA
 THOMSON
 THORENS
 TORNADO
 TOSHIBA
 TRICITY BENDIX
 TURBO
 UHER
 UNITRA
 UNIVERSUM
 UNKNOWN
 VIEWSONIC
 VOLTA
 VOSS-ELECTROLUX
 VOX
 WATSON
 WEGA
 WHIRLPOOL
 XER
 ZANKER
 ZANUSSI
 ZOPPAS

SHURE AMS8100 Instruction Manual

$4.99

SHURE AMS8100 - It's a complete owner's manual ( also known as operating manual or user guide), and it's in PDF format. After placing order we'll send You download instructions on Your email address. See below for delivery information

The manual is available only in language(s): English French Italian Spanish


Link to manual will be sent on Your email address after You place order.
This product was added to our catalog on Tuesday 15 April, 2008.
  Reviews  
  Write Review  
  Buy & Download  

Product Reviews
There are currently no reviews for this product.

Other reviews
pascal grandjean - 11/02/2009 5 of 5 Stars!
Excellent service. Service manuel conforme. C'est parfait. Merci!
Patrick Guice - 04/23/2008 5 of 5 Stars!
Phenomal manual great resoulution and very legible. Will become very helpfull in future for parts and service.
Jacek Madej - 08/30/2008 5 of 5 Stars!
Hi! love you!! schematics circuit best scan electronics area ...a have old radio grundig c8000 seek from net ... very done... hello best regard Edi from Poland
Dutra Lacerda - 02/17/2008 5 of 5 Stars!
All schematics for the Euro-PC and some extra info. Needed if you want to replace some missing hardware. A piece of great historical value and for vintage computing entusiasts.
Steve Fink - 07/24/2006 5 of 5 Stars!
Nice, really nice. I was happy to receive manual in true electronic form, instead of scanned original. This manual includes: Wiring diagram, circuit diagram, block diagram, PC board, adjustment, exploded view, PARTS CATALOG and more.. It's full color manual, not B&W or grayscale :)

Customers who bought this product also purchased
SHURE BETA87A User Guide
SHURE BETA87A User Guide
SHURE 200M PROLOGUE Owner's Manual
SHURE 200M PROLOGUE Owner's Manual
SHURE BETA98S User Guide
SHURE BETA98S User Guide
SHURE BETA58A User Guide
SHURE BETA58A User Guide
SHURE 1200 Service Manual
SHURE 1200 Service Manual
SHURE LXWIRELESSSYSTEM User Guide
SHURE LXWIRELESSSYSTEM User Guide

Click to see text excerpt from the manual
Dead Zone on MUTE IN DefeatDecrease Hold Time
As supplied, MUTEINis intended for use as amomentaryThe hold time can be decreased fromthe factory preset of
cough button or privacy function (mute when necessary).0.4 seconds to 0.3 seconds. (Less than 0.3 seconds is not rec-
However,iftheMUTEINisintendedto beused sothat thetalk-ommended.)
er must unmute microphones to enable speech pickup (un-Procedure:Install a 2 M resistor at jumpers X903.
mute when needed), this modification is needed. This re-
moves the muted channel from the MaxBus which eliminates
?dead zones.? A dead zone is an area in which a microphoneRemote Control of Link Global/Local, Off-Attenua-
picksupatalkerthroughamutedmicrophoneandothermicro-tion, Last Mic Lock-on, and Automatic/Manual DIP
phones do not activate for that talker.Switches
Procedure:Short jumper X115. Repeat these steps for allIf desired, these functions can each be remotely con-
channels needing modification.trolled with an SPST switch.
Procedure:
Change MUTE IN to Inhibit1. Solder a wire in the pc board jumper hole adjacent to the
As supplied, a channel will mute when its MUTE IN termi-desired function (printed on the pc board). Thesejumpers
nal is grounded. The mute function can be changed to ?Inhibit?are located just behind DIP switch SW902.
by an internal modification for each channel. After the modifi-2. Solder a wire in the pc board jumper hole marked ?GND?
cation, a logic ?Low? at the MUTE IN terminal prevents that
near switch SW902.
channel fromgating on if it is off, but allows it to remain on if it is
already on. IMPORTANT:To prevent high-frequency oscilla-3. Set the desired DIP switch(es) to the Up position.
tion,neverconnectachannel?sGATEOUTtoitsown MUTEIN4. Run the jumper wires to the desired remote location and
unless the ?Inhibit? modification has been made.solder them to an SPST toggle switch. The wires can exit
Procedure:Short jumper X111. Repeat these steps for allthe AMS8100 chassis above the DIP switches. Shorting
channels needing modification.any wire to the Ground wire will set the function(s) to the
corresponding switch ?down? position.
Change OVERRIDE IN to MUTE IN for Use with Fili-
buster ModeRemote Volume Control of Channels
This modification should only be performed with theUsing an external VCA(Voltage Controlled Amplifier), the
ChangeMUTEINtoInhibitmodification described above.level of a channel, the aux, or the master can be remote con-
trolled via a DC voltage. An example of an external VCA is the
Procedure:Short jumper X113. Remove resistors R1046ST-VCA1 from Radio Design Labs. They can be reached by
andR1058.Repeatthesestepsforallchannelsneedingmodi-
phone at 1--800--281--2683, or on the Internet at
fication.www.rdlnet.com.
For channel control ? Perform DirectOuttoPost-Fader
Change Off-Attenuation LevelSend/Returnmodification. Connect thetip ofa 1/4-in.connec-
This modification changes the off-attenuation level fromtor to the line input of the VCA, and the sleeve to the ground of
-15 dB to a selected value. Select from the following resistorthe VCA. Connect the ring to the line output of the VCA. Plug
values.the 1/4-in. connector to the Direct Out jack of the AMS8100.
The channel?s level control should be set at 5.
Off-Attenuation LevelResistor ValueFor Aux In control ? Connect the external source to the
10 dB18 k
VCA line input. Connect the VCA line output to the tip and
20 dB50 ksleeve of the AMS8100 Aux input. The Aux control should be
30 dB150 ksetat5.
Procedure:Remove resistors R9088 and R9145. InstallFor Master control ? Connect AMS8100 Line output to
new resistor at jumper points X904 and X908.theVCAlineinput. ConnecttheVCAlineoutputto theexternal
device (amplifier, tape recorder, etc.). Set Master control at 5.
Increase Hold Time
Using Multiple Gates to Drive a Single Relay
In place of the DIP switch SW902 option of 1.0-secondWhen using muliple gates to drive a single relay, the relay
hold time, the hold time can be increased to 1.5 seconds.may fail to release when gate out changes state.
(More than 1.5 seconds is not recommended.)
Procedure:Usingasolderingiron,removetwo30kresi-
Procedure:Install a 470k resistor across jumper pointssitors from the circuit path.
X902. Move DIP switch down to 1.0-second position.
For example, if Gate Out #7 is in parallel with other Gate
Outs to drive one relay, remove resistors R9026 and R9027.
Or, if Gate Out #1 is in parallel to drive one relay, remove resis-
tors R9039 and R9041. Do the same for any Gate Out used in
parallel with any other gate out.
Thismodificationshouldnotbenecessaryifarelayiscon-
trolled by only one Gate Out.
Eng h --22lis
Shopping Cart more
0 items
Log In
Reviews more
Write ReviewWrite a review on this product!
Payments
PayPal
PayPal
Information
Shipping & Returns
Privacy Notice
Conditions of Use
List of Manuals
Contact Us
What's New? more
SD-170EKE
SD-170EKE
Quick Start

$4.99
Current Parse Time: 0.083 s with 42 queries. Queries took 0.008128