Sharp COM Redirection Software does not operate.
AN-LS1 cannot be found by a search.
\ Check the connection. (Refer to OWhen connecting AN-LS1 to a computer using network (LAN)-
connection� in Troubleshooting page 47.)
\ Check the network settings. (Refer to OCheck the network settings for the computer and AN-LS1�
in the Troubleshooting page 48.)
\ In the case of Windows 2000/XP, is TCP/IP Filtering activated?
Invalidate the software or change the settings of the software so that the number of the Port setting
in the Search dialog can go though.
\ If a firewall is on the network system, there may be instances when a search cannot be carried out.
In this case, change the port number for search in the OSetting� dialog. (If AN-LS1 cannot still be
found, contact your network administrator.)
\ When AN-LS1 cannot be found even after trying the above solutions, specify the IP address directly.
(Page 35)
Addition cannot be made in OAdd�.
\ There are no more COM ports available, no addition can be made. By taking step 5 of OChanging/
Removing the Software� (page 44), select OModify� and click ONext>�. A screen will be displayed
where you can add COM ports, so that necessary COM ports can be added.
The status stays OBusy�, does not become OReady�.
\ A connection cannot be made if it is connected to other computers.
\ When auto logout was set to Odisable� and the network connection was not disconnected with
normal procedures, the status may be displayed as OBusy� at the time of next connection. In this
case, turn off the power supply for AN-LS1 and turn the power supply on again, or connect via
Telnet to select ODisconnect All� from SETUP MENU and execute.
A connection cannot be made because you have forgotten your user name or your password.
\ Initialize the settings. (Page 24)
After the initialization, carry out setting again.
" To initialize the settings for AN-LS1 to the factory default settings, connect the plug for the AC
adapter to a wall outlet to supply the power while pressing the Initialize (INIT.) button using a
pointed tool.
Initialize (INIT.) button
Images cannot be transferred using Sharp Advanced Presentation Software.
\ When using this software via the Virtual COM port and/or the RS-232C (PROJECTOR) terminal,
Appendixthe following functions cannot be used:
" Presentation Transfer
" Capture & Transfer
" Quick Transfer
51 |