Main Sub
ContentsDetails of function/operation
codecode
4106OC cover float detection [Function]
level (OC FLOAT LEVEL) When this test command is executed, the current set value is displayed. When [OK (ENTER)/START]
(Disabled when set to OC) key is pressed, the mirror base unit moves to the SPF scan position to acquire the OC cover float
(Executable only when the detection level.
SPF/RSPF is installed.)When the mirror base unit returns to the home position, the acquired value is displayed.
If the detection level is not acquired, ERR display is made. (Default: 0)
Note that, this test command must be executed with the OC cover closed.
If the value is 0, float detection is not performed in normal jobs.
[Operation]
1) Initial display<Canceling - when C/CA key is pressed->
41-06 OC FLOAT LEVELAfter canceling, the machine goes into the sub code entry
0 standby mode.
2) [OK (ENTER)/START]THE JOB IS BEING
CANCELED.
41-06 OC FLOAT LEVEL
EXECUTING...3) When the level is acquired:
41-06 OC FLOAT LEVEL
**** OK
3) When the level is not acquired:
41-06 OC FLOAT LEVEL
**** ERR
4301Fusing temperature setting [Function]
(Normal copy) (FU TEMP)When this test command is executed, the current set code number is displayed. Press [?/?/10KEY]
key to change the setting and press [OK (ENTER)/START] key to save the setting into the EERPOM.
The machine goes into the sub code entry standby mode.
CodeSet temperature (!C)Remark
0160
1165
2170
3175
4180
5185
6190Default
7195
8200
[Operation]
The operation is similar to test command 21-01.
04Fusing temperature setting [Function]
in multi coy (FU TEMP For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the temper-
MULTI)ature set with test command 43-1 to the temperature set with this test command.
When this test command is executed, the current set code number is displayed. Enter the code num-
ber and press [OK (ENTER)/START] key to change the setting.
CodeSet temperature (!C)Remark
0155
1160
2165
3170Default
4175
5180
[Operation]
The operation is similar to test command 21-01.
AR-M150/M155/M155X TEST COMMAND, TROUBLE CODES 10 - 16 |