14) Remove the left side cabinet.19) Use the flat cable to connect the printer I/F PWB and the printer
I/F unit. At that time, be careful of the connector direction. Also
check that the flat cable protector section (black section) passes
through the chassis edge. Bend the flat cable at the right angle
in two positions. Fix the flat cable with the cable clamp of the
printer I/F unit section and the flat cable clip.
15) Remove the cabinet angle. This angle is unnecessary when re-
moved. However, the screw which was fixing the angle is re-
quired to fix the printer I/F connector unit later.
20) Connect the wake up signal harness connector to the printer I/F
PWB, and connect the other end to the main harness wake up
signal connector.
16) Open the printer I/F connector window of the left rear cabinet.
(Cut the cabinet with nippers.)
21) Install all the parts that were removed to their original positions.
22) Connect the main unit and the printer controller with the printer
cable.
Caution label
17) Attach the printer I/F PWB with the accessory screw.
23) Attach the caution label to the cabinet. (Only EU version)
18) Use the screw noted in procedure 15) and attach the printer I/F
connector unit.3. Setting
1) Turn on the power of the unit.
2) Enter the simulation 26-1 mode.
(NOTE)
When attaching the I/F connector mounting plate, be caref3)ul notPress to"PRN: AR-PE1" button. (Communication between the unit
apply an excessive stress to the connector which is passed under theand the printer controller is allowed.)
I/F connector mounting plate.4) Cancel the simulation mode.