AV-32220
    ADJUSTMENT
B1 POWER SUPPLY
Measuring
IteminstrumentTest pointAdjustment partDescription
Check ofDC Voltmeter B1 (B11. Receive a black-and-white signal. (Color off)
B1 POWERConnector2. Connect the DC Voltmeter toB1connector ` pin (TP-91)
`` pin)
SUPPLY``and TP-E(#) (B1 connector b pin).
(TP-91)
3. Confirm that the voltage is DC134V?2V.
TP-E(#)
(B1
Connector
bbbb pin)
ADJUSTMENT OF IF. VCO
Measuring
ItemTest pointAdjustment partDescription
instrument
IF VCOSignalCW TRANSF." Under normal conditions, no adjustment is required.
adjustmentgenerator1. Receive a NTSC aer. broadcast.
[VCO(CW)] MODE
2. Select the VCO (CW) mode from the SERVICE MENU.
3. Confirm the color change (yellow) from HIGH LEVEL
to
LOW LEVEL
by CW TRANSF. and SYNC : YES being
HIGH LEVEL
shown on the screen. Then, adjust CW TRANSF. until
REFERENCE LEVEL
YELLOW
LOW LEVELREFERENCE LEVEL
mark turns yellow and confirm again
SYNC : YES being shown on the screen.
SYNC : YES
ADJUSTMENT OF RF AGC
Measuring
ItemTest pointAdjustment partDescription
instrument
RF. AGCNo.19 RF AGC1. Receive a broadcast.
adjustment2. Select ?No.19 RF AGC? of the PICTURE MODE.
3. Press the MUTING key and turn off color.
4. With the MENU LEFT key, get noise in the screen picture. (0
side of setting value)
5. Press the MENU RIGHT key and stop when noise disappears
from the screen.
6. Change to other channels and make sure that there Is no
irregularity.
7. Press the MUTING key and get color out.
ADJUSTMENT OF FOCUS
Measuring
ItemTest pointAdjustment partDescription
instrument
FOCUSSignalFOCUS VR" SET VIDEO STATUS to ?STANDARD?
adjustmentgenerator[In HVT]1. Receive a crosshatch signal.
2. While looking at the screen, adjust FOCUS VR so that the
vertical and horizontal lines will be clear and in fine detail.
3. Make sure that the picture is in focus even when the screen
gets darkened.
Note :
The final adjustment of convergence must be done after the
FOCUS adjustment. (Convergence is changed by FOCUS
adjustment.)
When makes difference by FOCUS adjustment, should be
reconfirming purity adjustment.
20No. 51782 |