n RESET TO 3200K OR 5600K WHITE BALANCE3. Set the pedestal level to 7.5IRE (0.050V) with the Up
When the white balance setting is set to either OP SETswitch and the Down switch.
3.2K� or OP SET 5.6K� the white balance will be automati-
cally set to the color temperature 3,200K or 5,600K
NO.1 ** INITIAL **
respectively.
R GAIN +....I....-
n BLACK BALANCE ADJUSTMENTB GAIN +....I....-
T PED +....I....-
R PED +....I....-[ADJUSTMENT by CAMERA]
Press the ABC (UP) Switch for over 1 second and theB PED +....I....-
black balances for 0dB, 9dB and 18dB will be automatical-PAINTING OFF
ly set in 5 seconds.
If the painting switch is ON in the page No.1 of INITIALRET END
SET menu, black balance fine adjustment can be per-
formed with the red gain/blue gain control.
[ADJUSTMENT WITH RCU OR RCB]
[ADJUSTMENT WITH RCU (RCB)]
Set the auto white/auto black set switch to ABC and the
Adjust the total pedestal level to 7.5IRE with the total
black balance will be automatically set regardless of cam-
pedestal adjustment.
era mode. While the system is being set, the auto warning
indicator (LED) blinks and it goes out when the black bal-Minimize the carrier wave using
the red & blue gain controls
ance setting is completed. If the lamp remains lit, ABC
should be tried again.
n TOTAL PEDESTAL LEVEL ADJUSTMENT
7.5 IRE
(Use an oscilloscope or a waveform monitor for this adjust-(0.050V)
ment.)
[ADJUSTMENT by CAMERA]
1. Select the page No.1 of the INITIAL SET menu on the
monitor screen.
2. Select OT PED� with the item switch.
-28- |