Preparation
Prepare the following items before the installation. The necessary items and their lengths differ depending on condition.
Preparing the necessary items
Item
Item number/Recommended typeUse
DC power cableUL type SVT (2 line cores) or equivalents*1 Necessary when supplying DC power
from the control unit to iris cameras
Maximum distance: 20 mSolder both ends of the cable with M3
screw clamp terminals.
Coaxial cableUL Listed NEC type CM orFor communication between iris
CL2, RG-6/U typecameras and the control unit
Recommended distance: 20 m or lessSolder both ends with BNC plugs.
Maximum distance: 100 m
LAN cableUL style 1666, CSA-FT4 or equivalentsNecessary for communication between
the administration PC and the control
*2
10Base-T/100Base-TX (Category 5)unit
Anchor boltM8Necessary for mounting the control unit
over the wall with the unicorn anchor
Unicorn anchor UC-830 or equivalentsNecessary for mounting the control unit
over the wall
1
*Flexible Metal Conduit (According to NEC)
22
Total area: 823.9 mm/100 % {1.277 in./100 %}
Trade size: 31.75 mm {1-1/4 in.}
Total number of Dimension and percent area of
iris cameras connectedconduit and tubing
1437 mm2/53 % {0.677 in.2/53 %}
2255 mm2/31 % {0.396 in.2/31 %}
2
*Cables with connector covers are unusable.
Note: When you use the GATE 1, GATE 2, and/or ALARM OUT connectors you need another cable suited for the connectors of
the external device or control unit. Use the UL style 1571 or equivalents, AWG 22 -16 wire.