2. Emergency Memory Address2-1. EMG Code (Emergency Code)
The codes shown in the following table which correspond to errors
Page FAddress 10 to 1Bthat occur are recorded in addresses 10, 14, and 18.
CodeType of Emergency
AddressContents
00No error
101st EMG code
10Loading motor time-out during load
12Upper: MSW code when the mechanism starts
shifting the 1st time11Loading motor time-out during unload
Lower: MSW code when the 1st emergency occurs20T reel emergency (reel slack) during unloading
13Lower: Target MSW code of the 1st emergency21S reel emergency (reel slack) during unloading
occurs
22T reel emergency
142nd EMG code23S reel emergency
16Upper: MSW code when the mechanism starts30FG emergency at the start up of the capstan
shifting the 2nd time
31FG emergency during the normal rotation of the
Lower: MSW code when the 2nd emergency occurs
capstan
17Lower: Target MSW code of the 2nd emergency
40FG emergency at the start up of the drum
occurs
41PG emergency at the start up of the drum
18Last EMG code
42FG emergency during the normal rotation of the
1AUpper: MSW code when the mechanism starts
drum
shifting the last time
43PG emergency during the normal rotation of the
Lower: MSW code when the last emergency occurs
drum
1BLower: Target MSW code of the last emergency
occurs44Phase emergency during the normal rotation of the
drum
When there are no emergency, data 00 will be written in the above
addresses (10 to 1B). When the first emergency occurs, the data
corresponding to the emergency will be written in the address (10
to 13) for this first emergency. In the same way, when the second
emergency occurs, the data corresponding to the emergency will be
written in the address (14 to 17) for this second emergency.
The data corresponding to the emergency occurring the last will be
written in the address (18 to 1B) for this last emergency.
Therefore the data of addresses 18 to 1B are renewed each time an
emergency occurs.
Note 1:Be sure to rewrite the data of addresses 10 to 1B to 00 after repairs/
adjustments.
Note 2:When rewriting the data, be sure to press the PAUSE button of the
remote commander after setting the data.
5-50 |