CFD-S20CP
SECTION 4SECTION 5
MECHANICAL ADJUSTMENTSELECTRICAL ADJUSTMENTS
PRECAUTION TAPE SECTION 0 dB = 0.775 V
1. Clean the following parts with a denatured-alcohol-moistened
swab :Y Standard Output Level
record/playback headpinch roller
Output terminalHP OUT
erase headrubber belts
capstanidlersload impedance& 32
2. Demagnetize the record/playback head with a head demagne-output signal level0.25 V (�10 dB)
tizer. (Do not bring the head magnetizer close to the erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
Y Test Tape
4. The adjustments should be performed with the rated power
supply voltage (9V) unless otherwise noted.TypeSignalUsed for
WS-48A3 kHz, 0 dBtape speed adjustment
Torque Measurement
ModeTorque meterMeter readingTape Speed Adjustment
Procedure:
2.95 � 6.86 mN Y m
Mode: playback
FWDCQ-102C(30 � 70 g Y cm)
digital frequency
(0.42 � 0.97 oz Y inch)test tape
counter
WS-48A
0.15 � 0.53 mN Y m
FWD(3 kHz, 0 dB)
CQ-102C(1.5 � 5.5 g Y cm)
Back Tension32 &
(0.021 � 0.076 oz Y inch)
more than 5.88 mN Y mset
FFCQ-201B(more than 60 g Y cm)
(more than 0.83 oz Y inch)
i jack (J321)
more than 5.88 mN Y m
REWCQ-201B(more than 60 g Y cm)Adjust so that the value on the digital frequency counter is
(more than 0.83 oz Y inch)3,000 Hz.
Specification Value:
Digital frequency counter
Tape Tension Measurement
2,940 to 3,060 Hz
ModeTension meterMeter Reading
more than 100 gAdjust so that the frequency at the beginning and that at the end of
FWDCQ-403A
tape winding are between 2,970 to 3,030 Hz.
(more than 3.53 oz)
Adjustment Location:
Tape speed adjustment
control inside motor