CFD-S26L/S36L
TUNER SECTION 0 dB = 1 ?VFM IF ADJUSTMENT
Y FM SectionAdjust for a maximum reading on level meter.
Setting:T2
RADIO (BAND) button: FM
10.7 MHz
FM RF signal
generator
FM FREQUENCY COVERAGE
TP (JW2)ADJUSTMENT
0.01 ?FFrequency Display87.5 MHz108 MHz
setReading on Digital voltmeter1.3 ? 0.3 V3.0 ? 0.2 V
75 kHz frequencyAdjustment Part<confirmation>L2
deviation by 1 kHz signal
output level : as low as possible
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
Y AM SectionL1CT1
Setting:
87.5 MHz108 MHz
RADIO (BAND) button: MW or LW
AM RF signalMW IF ADJUSTMENT
generator
Put the lead-wireAdjust for a maximum reading on level meter.
antenna close toT1
the set.450 kHz
30% amplitude
modulation byMW FREQUENCY COVERAGE
400 Hz signalCHECK
Frequency Display531 kHz1,611 kHz
Y Connecting Level Meter (FM, MW and LW)Reading on Digital voltmeter1.0 ? 0.5 V5.2 ? 0.6 V
Adjustment Part<confirmation> <confirmation>
level meter
(range: 0.5�5 V ac)MW TRACKING ADJUSTMENT
32 &
Adjust for a maximum reading on level meter.
setL3-1CT3
621 kHz1,404 kHz
i jack (J321)
LW FREQUENCY COVERAGE
ADJUSTMENT
Y Connecting Digital Voltmeter (FM, MW and LW)
Frequency Display153 kHz279 kHz
digitalReading on Digital voltmeter0.6 ? 0.3 V5.0 ? 0.1 V
voltmeterAdjustment Part<confirmation>L4
100 k&
TP (VT)LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-2CT5
162 kHz261 kHz
Y Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finallyAdjustment Location: See page 14.
done by the trimmer capacitors.