HCD-NEZ3/NEZ5
SECTION 4
TEST MODE
COLD RESETCD ERROR HISTORY
* The cold reset clears all data including preset data stored in*This mode can be used for CD error history display.
the RAM to initial conditions. Execute this mode whenProcedure:
returning the set to the customer.1. Set the FUNCTION to CD.
Procedure:2. While pressing the [DSGX] button, press the CD u button
1. Press theI/1 button to turn the power on.and turn the [VOLUME] knob in the counter-clock wise.
2. While pressing thex button, press theI/1 button and turn3. CD error history is displayed on the liquid crystal display. Each
the [VOLUME] knob in the counter-clock wise.timel m orM L button is pressed, CD error history
3. The message ORESET� is displayed and the set is reset.is changed.
PANEL TESTCD POWER MANEGE
* All segments of liquid crystal display are tested, and the version*This mode is for switch the CD power supply on/off. Even if
and released date of the micro computer are displayed.this state pulls out AC plug, it is held.
Procedure:Procedure:
1. Press theI/1 button to turn the power on.1. Press theI/1 button to turn the power on.
2. While pressing the [DSGX] button, press thel m button2. Set the FUNCTION to CD.
and turn the [VOLUME] knob in the counter-clock wise.3. Press theI/1 button again to turn the power off (standby).
Then all segments of liquid crystal display are turned on.4. While pressing the CD u button, press theI/1 button.
3. Press the [DSGX] button, the version and released date of the5. If turns power on and display OCD POWER�, then display
micro computer are displayed.OON� or OOFF�.
example of display:
1119 V006
Version of micro computer
(In this case, version 006)
released date of micro computer
(In this case, released of November 19)
4. Press the [TUNER/BAND] button, the model name and
distination are displayed.
example of display:
NE ASIA2
distination
(In this case, Asian model)
model name
(In this case, HCD-NEZXX)
5. Press the [PLAY MODE/TUNING MODE] button, OKEY 0 0� is
displayed on the liquid crystal display, and key test mode in.
Each time a key is pressed, the numerical value corresponding
to each key is displayed on the liquid crystal display.
6. To exit from this mode, perform the OCOLD RESET�.
TUNER STEP CHANGE-OVER
* Either the 9 kHz step or 10 kHz step can be selected for the
AM channel step.
Procedure:
1. Set the FUNCTION to AM, and press theI/1 button to turn
the power off.
2. While depressing the [TUNER/BAND] button, press theI/1 button.
3. The message O9K STEP� or O10K STEP� is displayed on the
liquid crystal display, and thus the channel step is changed
over.
12 |