CP-S210 (C10S)
6-6 The Air filter
The air filter should be cleaned about every 100 hours. If the indicators or a message prompts you to clean the
18
temperature rises and could cause malfunction.
WARNING Please carefully read the "User?s Manual - Safety Guide".
? Before replacing the air lter, make sure the power switch is off and the power cable is not plugged in.
18Type number: NJ08292
? Do not use the projector with the air lter and lter cover removed. The use without the air lter could result
in damage.
CAUTION Do not reset the filter timer without cleaning or replacing the air filter.
? If the air lter becomes clogged by dust or the like, internal temperature rises and could cause malfunction.
18
? When you replace the lamp, please replace also the air lter. The air lter may be attached to the replace-
ment lamp.
Caring For The Air filter
1. Turn off the projector, and unplug the power cord.
2. Apply a vacuum cleaner to the top of the filter cover to clean the air filter.
3. Reset the filter timer, according to following "Reset The Filter Timer".Filter Cover
(1) Turn on the projector. While the projector running, press the MENU button
to open the menu.
(2) Choose the "OPTION" on the menu using / the button, then press
the button or ENTER button.
(3) Choose the "FILTER TIME" using / the button, then press and hold button the of projector or
the RESET button of remote control for 3 seconds.
(4) Choose the "RESET" using the button.
Replacing The Air Filter
If the soiling will not come off the air filter, or it becomes damaged, then it needs to be replaced. Please replace
the air filter as soon as possible.
1. Turn off the projector, and unplug the power cord.
2. Contact your local dealer to prepare a new air filter. Tell the dealer your air filter type Filter cover
number.
18
Hold the release buttons of the filter cover, while pulling up it.
4. Hold the release buttons of the air filter, while pulling down it. Release buttons
5. Insert a new air filter, and replace the filter cover.
6. Reset the filter timer, according to following "Reset The Filter Timer".
(1) Turn on the projector. While the projector running, press the MENU button to Release buttons
open the menu.
(2) Choose the "OPTION" on the menu usin/g t hbeu tton, then press the
button or ENTER button.
(3) Choose the "FILTER TIME" using / the button, then press and hold the Air filter
button of projector or the RESET button of remote control for 3 seconds.
(4) Choose the "RESET" using the button.
1822 |