Setting the Fan Speed Notes
Notes
Y Press 4 to select:-Y If the unit is not going to be used for an extended
Y Do not adjust the vertical airflow direction louver downward
There are five stages of fan speed in addition toduring Cooling and Soft Dry. Drops of water may condenseperiod of time, turn off the main power supply. If it is
Auto Fan speed.on the air outlet vent and drip down.left at the ON position, approximately 2.8 W of
Y Use the remote control to change the vertical airflowelectricity will be used even if the indoor unit has been
AUTOdirection louver. Using your hands to adjust the directionturned off with the remote control.
FAN� Heatingmay cause the louver to malfunction. If this happens, stopY If operation is stopped, then restart immediately, the
When the temperature of the dischargeunit will resume operation only after 3 minutes.operation immediately and restart.
air increases, the fan speed increases.
Cooling Dry Setting the Horizontal Airflow Direction.
Operation Details
Changes the fan speed to generate aY Press 6 to select:-
cool breeze. The air starts to blow out
COOL � Cooling Operation
Indoorapproximately 40 seconds after the start
Y To set the room temperature at your preference
of Cooling or Soft Dry.HorizontalUnit
cooling comfort.
Airflow
Setting the Vertical Airflow Direction.
Direction RemoteAUTO
Y Press 5 to select:-AUTO � Automatic Operation
Control
Y Sense indoor temperature to select the optimum
AUTO
mode.
Y Temperature is not displayed on the remote control
AUTOY For COOL/DRY operation.
Louvers swing horizontally at a fixedduring AUTO operation.
AUTOY For COOL/DRY operation.speed.
Swing up/down automatically.DRY � Soft Dry Operation
AUTOY For HEAT operationY Dehumidifies while maintaining the setting
AUTOY For HEAT operationWhen air temperature is low, air is senttemperature. The Soft Dry Operation is recommended
When the discharge air temperature isin . When temperature goes up,during the rainy season.
low such as at the start of the heatinglouver swing horizontally at a fixedY If the room temperature exceeds the setting
operation, the air blows at horizontalspeed.temperature, operation switches to Cooling.
level. As the temperature rises, the hotY The fan speed is rather slow during Soft Dry
air blows in a downwards direction.Operation.
Use this air conditioner under the following
Y The humidity may not decrease when the indoor
conditions:
temperature is lower than the setting temperature on
Louver adjustment range
Unit in !Cthe remote control.
IndoorOutdoor
YThe adjustment range is differentHEAT � Heating OperationDBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT WBT DBT WBT
Dry Softfor each operation i.e. Heating,Y To warm up the room temperature upon your
Cooling,Cooling and Soft Dry. (Fig.at left)preference setting temperature.
FanMaximum Temperature-Cooling32234326
YThe angle indicated on the remote(Maximum Temperature-Heating) (30)Y Heat is obtained from outdoor air to warm up the(-)(24)(18)
control is different from that on theroom. When the outdoor ambient air temperature
About 30!
Minimum Temperature-Cooling16111611falls, the heating capacity of the unit might be
indoor unit.
Heating(Minimum Temperature-Heating) (2)(-)(-5)(-6)reduced. We recommend that you use an additional
About 30!
YThe louver angle automatically
heating device when the outdoor ambient air
changes to prevent condensation
temperature is low.
during Cooling and Soft Dry.
YWhen operation stops, the louverFAN � FAN Operation
About 60!automatically closes.Y Circulates air throughout the room.
Y Purifies and deodorizes the air if the air purifying filter
is used. Fan Operation is recommended during
seasons in which neither Heating nor Cooling is used.
* Five stages of adjustments can be made in this range.
6 |