Electrical connections
Any electrical work required to install thisThe cooker should be connected to a double pole
hob should be carried out by a qualifiedswitch with a minimum gap of 3 mm. between the
electrician or competent person, inswitch contacts and of a type suitable for the required
accordance with the current regulations.load in compliance with the current electric
regulations. The switch should be sited within 2m of
the hob and be easily accessible upon completion of
THIS COOKER MUST BEthe installation.
EARTHED.
The switch must not break the yellow and green earth
cable at any point.
The manufacturer declines any liability
Ensure that the hob supply cord does not
should these safety measures not be
come into contact with surfaces with
observed.temperatures higher than 50 deg. C.
This cooker is designed to be connected to
Supply Cable Specifications
a 230-240V 50Hz AC electrical supply.
Before switching on, make sure the electricity supplyFor Uk use only
voltage is the same as that indicated on the hob rating
Connection Min. sizeCable / flex Fuse
plate. The rating plate is located on the bottom of the
viaCable/flex type
hob. A copy is attached on the back cover of this
2
book.Y Cooker3 x 6 mmH05 VV-F 30 A
Control
Circuit
The cooker is supplied without supply cord. A 3 core
flexible supply cord must be fitted, in accordance
For Europe use only
with the specification given in the relevant tables.
Min. size Cable/flex Cable / flex typeFuse
1) Loosen the two fixing screws securing the
+back protective screen of the cooker3x 2.5 mm, then lift2
H05 RR-F30 A
it up and remove it. This will expose the
terminal block on the right bottom corner.
2) Loosen the two cable clamp screws and lift
the top section of the clamp enough to allow
the cable to be passed through.
3) Connect the red (live) wire to the terminal
which is marked with the letter "L".
4) Connect the black (neutral) wire to the
terminal which is marked with the letter "N".
5) After fitting a green or yellow/green sleeve
over the bare copper wire (earth wire), connect
the exposed end to the terminal which is
marked with the earth symbol or with the
letter "E"coloured green and yellow.
NOTE:FO 2375
The earth wire should be about 2 cm. longer
than the live and neutral wires.
6) Secure the cable by means of the clamp screws
and refit the back protective screen.
21 |