INTRODUCTION
WARNING: THIS COOKER MUST BE EARTHED
The cable must be routed away from potentially hot
areas marked by X in the diagram below.
RATING PLATE
Record the model, product and serial numbers on the
back cover of this instruction book from the rating
plate. This is situated on the lower front frame of the
cooker and can be seen upon opening the top oven
door.
To move the cooker, open the fan oven door, and lift
the cooker by holding inside the top of the
compartment.
The cooker must be protected by a suitably rated
fuse or circuit breaker. The rating of the cooker is
given on the rating plate.
Do not remove the rating plate from the cooker as
this may invalidate the guarantee.
INSTALLATION
If your cooker has been damaged in transit, contact
This is a type X appliance which means it is free-
your supplier immediately. DO NOT attempt to install
standing and can be fitted with cabinets on one or
it.
both sides. It may also be fitted in a corner setting.
Your cooker left the factory fully packaged to protectEnsure that the cooker is standing level.
it from damage. If it is delivered without packaging
and damage has occurred, the manufacturer cannotSide walls which are above hob level should be
accept responsibility. Contact you supplier for advice.protected by heat resistant non-combustible material
and MUST NOT be nearer than 40mm to the hob
Once the packaging has been removed the cookerside.
should only be moved by hand. DO NOT use a sack
barrow or any other aid to lift the cooker as damageA nominal air gap of 2mm at the sides of the cooker
may occur.is required to enable the cooker to be moved into
position. It is recommended that proprietary trims are
Connection to the electricity supply must be carriedfitted to protect the worktops of either side of the
out by a qualified electrician/competent person.appliance. These are available from most DIY
stores.
The electrical connection should be made using a
double pole isolating switch (cooker socket) with atAlways ensure an air gap is maintained at hotplate
least 3mm contact separation in all poles. The cablelevel. Tiles or other forms of deep wall covering
must have conductors of sufficiently high cross-should not obscure this gap.
sectional area to prevent overheating and
deterioration.
22
Six square millimetres (6.00mm)) iiss tthhee
rreeccoommmmeennddeedd ccrroossss--sseeccttiioonn aarreeaa..Air gap