CONVERSION OF GAS
Your cooker is designed to work with natural gas,
and is convertible for use witth propane or
butane.
The LPG conversion kit is available from your
Service Force Centre and must be fitted by a
Corgi Registered engineer.
For changing the gas type it is necessary to:
" replace the nozzles (hob, oven and grill);
" adjust the minimum level (hob and oven);
" check the gas connection;
Stick the label supplied with the
appliance (in the nozzles bag) corresponding
to the gas type utilised.
SPECIFICATION NOZZLES
Table no.1
(Cat : II 2H3+)
Normal SimmerBy-Nozzle Cons
Pressure
Burner power power pass Gas Type diameter
(mbar) 3
(kW) (kW) (mm) (mm) m/h g/h
Natural Gas 20 1.19 0,267 -
RAPID 3,00 0,72 0,42 Butane 28-30 0,88 - 218,1
Propane 37 0,88 - 214,2
Natural Gas 20 0.96 0,190 -
SEMI-
2,00 0,43 0,32 Butane 28-30 0,71 - 145,4
RAPID
Propane 37 0,71 - 142,8
Natural Gas 20 0.70 0,095 -
AUXILIARY 1,00 0,35 0,29 Butane 28-30 0,50 - 72,7
Propane 37 0,50 - 71,4
Natural Gas 20 1.16 0,267 -
OVEN 3,00 1,10 0,46 Butane 28-30 0,82 - 218,1
Propane 37 0,82 - 214,2
Natural Gas 20 0,96 0,190 -
GRILL 2,00 - - Butane 28-30 0,71 - 145,4
Propane 37 0,71 - 142,8
23 |