CS-A18CKPG CU-A18CKP6G
8.2. Soft Dry Mode Operation
" The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
" During Soft Dry operation, the Indoor Fan will operate at SLo speed.
" Once room temperature reaches below Soft Dry OFF temperature. Indoor Fan, Compressor and Outdoor Fan stop for 6
minutes.
Time Delay Safety Control
" Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Anti-Freezing Control
" Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
Compressor Reverse Rotation Protection Control
" Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
Anti-Dew Formation Control
" Same as Anti-Dew Formation Control for Cooling Mode operation.
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
" Fan speed off and on at SLo speed.
" Deodorizing Control.
15 |