CVP09FR
7. Freeze preventive8.3. ONE-HOUR TIMER
When the indoor pipe temperature falls below 0oC during cool opera-When ONE-HOUR timer is set, the unit turns off automatically after
tion or dry operation, the compressor is turned off. And if the indoorone hour. The one hour timer operation has priority over other time
pipe temperature rises exceeds 4oC after 3 minutes, the compressoroperation, such as the TIMER ON and TIMER OFF. If the ONE-HOUR
will restart.TIMER button is pressed again during operation, the unit will operate
additionally for another one hour.
8. Timer
9. AUX Button
8.1. OFF TIMER
9.1. Test Run
Set the OFF-TIMER.
The unit will turn off automatically according to your setting. TimerIf the "AUX" button on the unit is pressed for 5 seconds or more during
duration can be set by 0.5 hours to maximum 12 hours. Up to 9.5operation, cool test operation starts. The operation LED (red) flickers
during test run. Continuous compressor on operation is performed.
hours, you can set by 0.5hours increments and from 10 to 12 hours, by
1 hour increment.During Test-Run mode, pump is always ON.
8.2. ON TIMER9.2. Aux Operation
Set the ON-TIMER.If the "AUX" button on the unit is pressed during operation OFF, cool-
The unit will turn on automatically according to your setting. Timering operation starts.
duration can be set by 0.5 hours to maximum 12 hours. Up to 9.5Then setting Temperature will be is automatically set.
hours, you can set by 0.5hours increments and from 10 to 12 hours, byDuring Aux mode, pump will be ON for 1 minute since start.
1 hour increment.
10. Test mode
Keep pushing the "AUX." buttons and supply the power, the system
will go to the test mode. In this mode, the output of operation is
switched by pushing the "AUX." button in the unit or the "OI" button in
the remote controller. Normal outputs are shown in "Self Check Mode
Table"
11. Diagnostic program
When indoor fan motor is out of order or compressor lock or abnormal water level occurs, the compressor, indoor fan motor, outdoor fan motor, and
louver are all stopped and the operation LED(red) turns on or off synchronously with the timing of the timer LED. When the thermistor for room tem-
perature or pipe temperature is open or short state, the operation LED turns on or off synchronously with the timing of the timer LED by pushing con-
tinuously for more than 5 seconds "AUX." button during suspension of operation.
1sec
ON4sec
Timer LEDOFF
1sec
ON
Indoor fan motor
OFF
ON
Outdoor fan motor
OFF
Operation LED
ON
Thermistor short state
OFF
ON
Thermistor open state
OFF
12. Drain Pump13. Plasmacluster
When drainage is accumulated the float switch becomes close condi-Whenever an indoor machine receives the signal of the plasma cluster
tion and the microcomputer detects this for 1 minute and cause tofrom remote control during air conditioner operation, the operation
operate drain pump. If it has passed for 3 minutes since the microcom-mode regarding at the plasmacluster changes in the order of the fol-
puter detects an error by photo interrupter circuit, Compressor will stoplowing.
and ALL LED will blink.
Clean mode ? OFF