CX-JN44
The 7th and 8th digit from the left indicates: The 5th and 6th digit from the left indicates:
(Motor status display)(Error step display)
The 7th and 8th digit from the left indicates which motor outputThe 5th and 6th digit from the left indicates which processing when
status when an error occurred is indicated.a trouble occurred
DisplayStatusDisplayContents
�0No table motor output01Power OFF in progress
�1Table motor forward output02Initialize in progress
�2Table motor backward output03Oscillation stopping
�3Table motor break output04From oscillation stop, oscillation starting
0�No loading motor output05Stopping
1�Loading motor forward output06Stop operation is under way
2�Loading motor backward output07Start operation in progress
3�Loading motor break output08TOC read in progress
09Search operation is under way
The 9th and 10 th digit from the left indicates:0APlayback operation is under way
(Tray status display)
0BPause operation is under way
The 9th and 10th digit from the left indicates which target processing
0CPlayback manual search operation is under way
when an error occurred is indicated.
0DPause manual search operation is under way
0EN
DisplayStatus
01Open operation
The 7th and 8th digit from the left indicates:
12Close operation
The 7th and 8th digit from the left indicates which operation in
18Ex-open operation
progress when a trouble occurred. (Step of each processing of the
5th and 6th digits is indicated)
2. Optical Pick-up Error Code Mode
? When this mode is entered, optical pick-up error code is5 REPEAT LIMIT CANCEL MODE
displayed with the 8-character format on the fluorescent? Number of repeat for CD playback is 5 times when the repeat
indicator tube.mode is OREPEAT�. This mode is used to enables CD to repeat
playback for limitless times.
The first digit from the left indicates:Procedure:
The first digit from the left indicates which mode the error history1. Press the?/1 button to turn the power ON.
is. In the optical pick-up error code mode, OD� is displayed on the2. Press the [CD] button to select OCD�.
fluorescent indicator tube.3. Press three buttons ofx , [CD] and [ENTER] simultaneously.
4. The message OLIMIT OFF� is displayed on the fluorescent
The second digit from the left indicates:indicator tube momentarily, CD repeat 5 limit is cancelled.
(Error history No. display)
The second digit from the left indicates which order the error history
is. O1� indicates the latest error history, and each time the number
increases by one, the error history goes back to one-previous error.
The third and 4th digit from the left indicates:
(Error status display)
The third and 4th digit from the left indicates which error status is
indicated.
DisplayStatus
01Not focused (TOC read without a disc)
02GFS NG (TOC read with a disc chucked)
03Start operation time-over
04Defocused continuously (Defocused during TOC
reading)
05Q code not entered for specified time
06Tracking not turned ON
07Blank disc (Blank disc TOC read)