HCD-FC8/FC9
Y Code list of Emergency HistoryY Error code (aa)
10: Communication to RF AMP (IC001) failed.FF : Complete the initializing. (normal operation)
11: Each servo for focus, tracking, and spindle is unlocked.11 : Stocker movement (to chucking position) failing in the midst
12: Check sum error of EEPROM (IC203).of initializing the mechanism deck.
14: Communication to servo DSP (IC401) failed, or servo DSP12 : Stocker movement (to chucking position) failing in the midst
(IC401) is faulty.of initializing the mechanism deck.
15: Communication to DVD decoder (IC701) failed, or DVD1x : Initializing the mechanism deck.
decoder (IC701) is faulty.2x : Initializing the mechanism deck.
16: Communication to DSD decoder (IC801) failed, or DSD3x : Initializing the mechanism deck.
decoder (IC801) is faulty.41 : Disc eject failing in the midst of initializing the mechanism
20: Initialization of sled servo failed. It is not placed in the ini-deck.
tial position.4x : Initializing the mechanism deck.
23: Sled servo operation error.50 : Disc eject failing in the midst of initializing the mechanism
24: Made a request to move the sled servo to wrong position.deck.
30: Tracking balance adjustment error.5x : Initializing the mechanism deck.
31: Tracking gain adjustment error.A2 : Disc eject failing in the midst of initializing the mechanism
33: Focus bias adjustment error.deck.
34: Focus gain adjustment error.Ax : Initializing the mechanism deck.
35: Equalizer adjustment error.D3 : Disc eject failing in the midst of initializing the mechanism
40: Focus servo does not operate.deck.
41: With a DVD dual layer disc, focus jump failed.Dx : Initializing the mechanism deck.
50: CLV (spindle) servo does not operate.Ex : Initializing the mechanism deck.
51: Spindle does not stop.
60: Made a request to seek nonexistent address.Y Error code (bb)
61: Seek error of retry more than regulated times.00 : Initializing the mechanism deck.
70: Control data could not be read.10 : Retry over of eject and loading.
80: Disc reading failed.30 : Open operation in no disc status.
60 : Retry over of eject and loading.
5. MECHA ERROR HISTORY70 : Disc is chucking position.
On the Test Mode Menu screen, selecting [5] displays the information81 : Retry failed of disc movement from chucking position to
of mechanism deck error history.stocker.
The history information from last 1 up to 8 can be scrolled with the83 : Retry preparation failed of disc movement from chucking
O key or o key. Also, specific information can be displayed byposition to stocker.
directly entering that number with ten keys.90 : Disc is stored in the stocker.
A1 : Retry failed of disc movement from stocker to chucking
### Mecha Error History ###position.
A3 : Retry preparation failed of disc movement from stocker to
1. aa bb cc dd xx xx xx xxchucking position.
2. aa bb cc dd xx xx xx xxB0 : Just before the release operation.
3. aa bb cc dd xx xx xx xxB1 : Retry failed of the release operation.
4. aa bb cc dd xx xx xx xx
5. aa bb cc dd xx xx xx xxY Error code (cc)
6. aa bb cc dd xx xx xx xx10 : Under a stop.
7. aa bb cc dd xx xx xx xx22 : Retry preparation failed.
8. aa bb cc dd xx xx xx xx23 : Retry failed.
Scroll:UP/DOWNY Error code (dd)
(1.Latest Err.)Exit: RETURN10 : Under a stop.
22 : Retry preparation failed.
23 : Retry failed.
aa : The error in the midst of initializing the mechanism deck.
bb : The error in the midst of loading operation.
cc : The error in the midst of up/down the stocker.
dd : The error in the midst of switching the mechanism deck mode.
xx : Not used.
33 |