HCD-X1
Note: Follow the disassembly procedure in the numerical order given.
HOW TO OPEN THE LOADING ASSY PANEL WHEN POWER SWITCH TURNS OFF
2Slide the chuck cam in the direction
of arrow to release the chucking.
1Open the cover dust.
3Draw out the loading assy panel
in the direction of the arrow.
DMB10 BOARD SERVICE POSITION
? In checking the DMB10 board, prepare four eNo. J-2501-239-A: 1.00 mm Pitch, 5 cores, Length 300 mm, Pxtension jigs (Part .art No
J-2501-242-A: 1.00 mm Pitch, 11 cores, Length 300 mm and Part No. J-2501-280-A: 5 cores, Length 300 mm).
Connect extension jig (J-2501-242-A) to the
MAIN board (CN503) and DMB10 board (CN106).DMB10 board
(CN4501)
DMB10 board
DMB10 board (CN401)
Connect extension jig (J-2501-280-A) to the
DMB10 board(CN106)MAIN board (CN508) and DMB10 board (CN401).
(CN202)
Connect extension jig (J-2501-242-A) to the
MAIN board (CN504) and DMB10 board (CN4501).
DMB10 boardMAIN board
(CN101)(CN504)
wire (flat type) 24 core
MAIN board
(CN508)
Note: DonOt remove the
wire (flat type) 24 core (CN101).
If you remove the
wire (flat type) 24 core (CN101),
MAIN board
solder the bridge of optical pick-up.
(CN503)
MS-203 board
(CN001)
Connect extension jig (J-2501-239-A) to the
DMB10 board (CN202) and MS-203 (CN001) board.
7 |