1-3. CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified value of OBase Band Block Adjustment� of OVIDEO
SYSTEM ADJUSTMENT� are satisfied.
1. 36 MHz Origin Oscillation Adjustment2. HALL Adjustment
(VC-210 board)For detecting the position of the lens iris, adjust the HALL amplifier
Set the frequency of the clock for synchronization. If degain and ofviatedfset. If de, theviated, iris can oscillate, or the indoor-outdoor
synchronization will be lost and the color will become inconsistent.white balance can mis-operate.
SubjectNot requiredSubjectNot required
Measurement Point!aPin of IC202 (CL200)Measurement PointDDS display data of LCD or monitor
Measuring Instrument Frequency counterMeasuring Instrument TV (Note 2)
Adjustment PageFAdjustment PageF
Adjustment Address1CAdjustment Address1E, 1F, 70
Specified Valuef=18000000 ? 90HzSpecified ValueWhen data of page: 6, address: 01 is
01. (Note 1)
Adjusting method:Data on display shall be: 88 to 8C.
1) Select page: 0, address: 01, and set data: 01.When data of page: 6, address: 01 is
2) Select page: F, address: 1C, change the data and set the clock03. (Note 1)
Data on display shall be: 15 to 19.
frequency (f) to the specified value.
3) Press the PAUSE button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.Note 1:The PAUSE button of the adjustment remote commander must be
pressed.
Note 2:DDS display data of LCD or TV monitor
CAM 00 0000
CAM 00 00XX
Object data
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 94, and set data: 8A.
3) Select page: 6, address: 95, and set data: 17.
4) Select page: 6, address: 01, set data: 6D, and press the PAUSE
button of the adjustment remote commander. (The HALL
adjustment is performed and the adjustment data is stored in
page: F, address: 1E, 1F and 70.)
5) Select page: 6, address: 02, and check that the data is O01�.
6) Select page: 6, address: 94, and set data: 00.
7) Select page: 6, address: 95, and set data: 00.
8) Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
9) Select page: 0, address: 01, and set data: 00.
Checking method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 6, address: 04, and set data: 03.
4) Select page: 6, address: 01, and set data: 01, and press the
PAUSE button of the adjustment remote commander.
5) Check the DDS display data (Note 2) lies within the O88� to
O8C� range.
6) Select page: 6, address: 01, set data: 03, and press the PAUSE
button of the adjustment remote commander.
7) Check the DDS display data lies within the O15� to O19� range.
8) Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
9) Select page: 6, address: 04, and set data: 00.
10) Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
11) Select page: 0, address: 01, and set data: 00.
5-9 |