4-2-3. Emergency Memory Address
Page CAddress 30 to 3BWhen there are no emergency, data 00 will be written in the above
address (30 to 3B). When the first emergency occurs, the data
corresponding to the emergency will be written in the first emergency
AddressContentsaddress (30 to 33). In the same way, when the second emergency
30EMG code when the first emergency has occurred.occurs, the data corresponding to the emergency will be written in
32Upper : MSW code of the machine status in whichthe second emergency address (34 to 37).
transition has started then the first emerThe data corresponding to the emergencygency occurring last will be
occurred.written in the last emergency address (38 to 3B).
Lower : MSW code when the first emergency hasTherefore the data of addresses (38 to 3B) are renewed each time
occurred.an emergency occurs.
33Lower : MSW code of the machine movement target
when the first emergency has occurred.Note:Be sure to rewrite the data of addresses 30 to 3B to 00 after
34EMG code when the second emergency has occurred.repairs/adjustment.
36Upper : MSW code of the machine status in which
transition has started then the second
emergency occurred.
Lower : MSW code when the second emergency has
occurred.
37Lower : MSW code of the machine movement target
when the second emergency has occurred.
38EMG code when the last emergency has occurred.
3AUpper : MSW code of the machine status in which
transition has started then the last emergency
occurred.
Lower : MSW code when the last emergency has
occurred.
3BLower : MSW code of the machine movement target
when the last emergency has occurred.
Adjustment procedure:
OrderPageAddressDataProcedure
100101Set the data.
30
31
32
33
34
2C3500After setting the data to each address,
36press the PAUSE button.
37
38
39
3A
3B
300100Set the data.
5-75 |