DCR-TRV33/TRV33E
3. Error Rate Check
3-1.Preparations before adjustments
ModeCamera recording (LP mode)
SubjectMoving object
Audio signal400Hz, �66 dBs signal: MIC jack left
and right. (Refer to Fig. 6-3-8.)
Adjusting method:
Order Page Address DataProcedure
1Set REC MODE (Note1) to LP.
2Record the camera signal for three
minutes.
Note1: TAPE SET of the menu settings.
3-2. ErroRate Checr k
ModePlayback
SignalRecorded signal at OPreparations before
adjustments�
Measurement PointMonitor TV, Headphone
Measuring Instrument
Adjustment Page1C (Note2)
Adjustment AddressB3 to C8
Specified ValuePlayback picture and sound are normal.
Note2: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
O00�.
Adjusting method:
Order Page Address DataProcedure
1Playback the recorded signal at
OPreparations before adjustments�
200101Set the data.
301000Set the data.
430108Set the data, and press PAUSE
button.
5Confirm that the playback picture
and sound are normal. If not,
proceed to step 9. (Note3)
630152Set the data, and press PAUSE
button.
7300Change the address.
8301Check that the data is O00�.
900100Set the data.
Note3: When playback picture or sound is abnormal, check the use tape,
clean the tape running surface, and perform re-adjustment.
Processing after Completing Adjustments
Order Page Address DataProcedure
1Set REC MODE to SP.
6-48 |