2. Flange Back Adjustment
(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
SubjectSiemens star chart with ND filter for
the minipattern box (Note1)
Measuring Instrument Adjustment remote commander
Adjustment PageF
Adjustment Address4E to 5D, 61
Note1: Dark Siemens star chart.
Note2: Check that the data of page: 6, address: 02 is O00�. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1) POWER.................................................................. CAMERA
2) NIGHT SHOT ..................................................................OFF
Preparations:Adjusting method:
1) The minipattern box is installed as shown in the followingOrder Page Address DataProcedure
figure.
Note: The attachment lenses are not used.100101Set the data.
2) Install the minipattern box so that the distance between it and268201Set the data.
the front of the lens of the camcorder is less than 3cm.360113Set the data, and press PAUSE
3) Make the height of the minipattern box and the camcorder equal.button.
4) Check that the output voltage of the regulated power supply is460127Set the data, and press PAUSE
the specified voltage.
5) Check that at both the zoom lens TELE end and WIDE end,button.
5602Check that the data changes to
the center of the Siemens star chart and center of the exposure
screen coincide.O01�. (Note3)
Note3: The adjustment data will be automatically input to page: F, address:
Specified voltage: The specified voltage varies according to the4E to 5D, 61.
minipattern box, so adjust the power supply
output voltage to the specified voltage writtenProcessing after Completing Adjustments:
on the sheet which is supplied with the
minipattern box.Order Page Address DataProcedure
168200Set the data.
Below 3 cm200100Set the data.
Minipattern box3Turn off the power and turn on
again.
Camcorder4Perform OFlange Back Check�.
Camera
table
Regulated power supply
Output voltage : Specified v?0.01Vdcoltage
Output current : more than 3.5A
Red (+)
Black (�)
Yellow (SENS +)
White (SENS �)Need not connected
Black (GND)
Fig. 5-1-6.
5-16 |