Contact Us
Privacy Notice
Shipping & Returns
Search for Manual:  
 
Search
 
Categories
 ACEC
 ACER
 AEG
 AIKO
 AIWA
 AKAI
 ALBA
 ALFATEC
 ALINCO
 ALNO
 ALPINE
 AMSTRAD
 AOC
 APPLE
 ARTHUR MARTIN ELECTROLUX
 ATAG
 ATLAS-ELECTROLUX
 BANG&OLUFSEN
 BARCO
 BAUKNECHT
 BECKER
 BEKO
 BELINEA
 BLAUPUNKT
 BOSCH
 BOSS
 BRANDT
 BRAUN
 BROTHER
 BUSH
 CANON
 CASIO
 CASTOR
 CLARION
 CLATRONIC
 COMMODORE
 COMPAQ
 CORBERO
 CRATE
 CROSSLEE
 CROWN
 CTX
 CURTISS
 DAEWOO
 DECCA
 DENON
 DIORA
 DOMETIC
 DUAL
 ELECTROLUX
 ELEKTRA
 ELEKTRA BREGENZ
 ELEKTRO HELIOS
 ELITE
 ERICSSON
 ESCOM
 FAURE
 FENDER
 FERGUSON
 FINLUX
 FISHER
 FLYMO
 FRIGIDAIRE
 FUNAI
 GELHARD
 GEMINI
 GOODMANS
 GRAETZ
 GRANADA
 GRUNDIG
 HAMEG
 HANSEATIC
 HARMAN
 HARMAN KARDON
 HEWLETT-PACKARD
 HITACHI
 HUSQVARNA
 HYUNDAI
 IAT
 IGNIS
 INFINITY
 INTEGRA
 ITT
 JBL
 JOHN LEWIS
 JUNO-ELECTROLUX
 JVC
 KAWAI
 KENWOOD
 KODAK
 KOERTING
 KORG
 KUPPERSBUSCH
 LADEN
 LG-GOLDSTAR
 LLOYDS
 LOEWE
 LUX
 LUXMAN
 LUXOR
 M-AUDIO
 MACKIE
 MARANTZ
 MARYNEN
 MATSUI
 MATURA
 MAX-FIRE
 MCCULLOCH
 MEDION
 METZ
 MICROVITEC
 MIELE
 MINOLTA
 MITAC
 MITSUBISHI
 MOFFAT
 MOTOROLA
 MTC
 NAD
 NAKAMICHI
 NEC
 NN
 NOKIA
 NORDMENDE
 NUMARK
 OKI
 ONKYO
 OPTIQUEST
 ORION
 OTHERS
 PACE
 PALLADIUM
 PANASONIC
 PARKINSON COWAN
 PARTNER
 PEACOCK
 PERICOM
 PHILIPS
 PIONEER
 POLAR
 POLAROID
 PRIVILEG
 PROGRESS
 QUELLE
 REVOX
 REX-ELECTROLUX
 RFT
 RICOH
 ROADSTAR
 ROLAND
 ROSENLEW
 ROTEL
 SABA
 SALORA
 SAMSON
 SAMSUNG
 SANGEAN
 SANSUI
 SANYO
 SCHNEIDER
 SEG
 SELECO
 SENNHEISER
 SEPPELFRICKE
 SHARP
 SHERWOOD
 SHURE
 SIEMENS
 SILENTIC
 SONY
 TANDBERG
 TAXAN
 TEAC
 TEC
 TECHNICS
 TELEFUNKEN
 TENSAI
 THERMA
 THOMSON
 THORENS
 TORNADO
 TOSHIBA
 TRICITY BENDIX
 TURBO
 UHER
 UNITRA
 UNIVERSUM
 UNKNOWN
 VIEWSONIC
 VOLTA
 VOSS-ELECTROLUX
 VOX
 WATSON
 WEGA
 WHIRLPOOL
 XER
 ZANKER
 ZANUSSI
 ZOPPAS

SONY DE555 Repair Manual

$7.99

SONY DE555 - It's a complete service manual, and it's in PDF format. It contains circuit diagrams ( schemas ) etc. It also usually contains parts catalog. After placing order we'll send You download instructions on Your email address. See below for delivery information

The manual is available only in language(s): English


Link to manual will be sent on Your email address after You place order.
This product was added to our catalog on Monday 07 May, 2007.
  Reviews  
  Write Review  
  Buy & Download  
The manual also covers models
DE556CKDE551

Product Reviews
There are currently no reviews for this product.

Other reviews
Carl Conti - 08/03/2006 5 of 5 Stars!
Thanks for manual for Luxman M02. I'll recomend this site to my friends for sure! Keep on the good work!
oleg volkozub - 09/25/2008 5 of 5 Stars!
Very nice clear manual with specifications, thanks!
Glen Meyer - 10/26/2008 3 of 5 Stars!
Very fast service, manual is well scanned and clear, but the Appendix A containing PC Command table and Control codes are missing
Roger Mason - 07/28/2006 5 of 5 Stars!
Man, I was looking for this manual for a while! Where do You get them?;) Of course, quality is goooood:) Anyway, I can only say: A+A+A+!
Anny ROY - 04/06/2007 5 of 5 Stars!
Super fast service and document of excellent quality. Thanks

Customers who bought this product also purchased
SONY 16229173 Service Manual
SONY 16229173 Service Manual
SONY 14DK1 Service Manual
SONY 14DK1 Service Manual
SONY 16229172 Service Manual
SONY 16229172 Service Manual
SONY 6R-33 Service Manual
SONY 6R-33 Service Manual
SONY 1400 Service Manual
SONY 1400 Service Manual
SONY 362B Service Manual
SONY 362B Service Manual

Click to see text excerpt from the manual
D-E551/E555/E556CK
SECTION 5
ELECTRICAL ADJUSTMENTS
Precautions for AdjustmentFocus bias CheckFocus/Tracking Gain AdjustmentThe waveforms are those measured with the oscilloscope set asAdjustment and Checking Location:
1. Before beginning adjustment, set the equipment to serCondition: viceA servo analayzer is necessary in order to perforshom this adjustmentwn below.
mode.Y Hold the set in horizontal state.exactly.Y VOLT/DIV: 500 mV� MAIN BOARD (Side A) �
After the completion of adjustment, be sure to reset the ser-Y TIME/DIV: 5 ms
However, this gain has a margin, so even if it is slightly off,
vice mode.Check Procedure:
there is no problem. Therefore, do not perform this adjustment.
For more information, see OService Mode (service program) �oscilloscope Y Waveform when tracking gain is lowered.
on page 8.(AC range)Focus/tracking gain determines the optical pick-up folloFundamental ww-up rela-ave appears. (large waves)
2. Perform adjustments in the order given.tive to mechanical noise and mechanical shock when the 2-axis
MAIN board
3. Use YEDS-18 disc (Part No.: 3-702-101-01) unless otherwise2 k Wdevice operates. However, as these reciprocate, the adjustment is
TP522 (RFO)+��� 0 V
indicated.at the point where both are satisfied.
TP520 (VC)�
4. Power supply voltage requirement: DC2.5 V in battery termi-Y When gain is rased, the noise when 2-axis device operates in-
nal(See page 11)crease.Fig. 1
VOLUME knob : MinimumY When gain is lowered, it is more susceptible to mechanical shock
RESUME switch : OFF1. Set the equipment to service mode stop state. (See page 8)and skipping occurs more easily.Y Waveform when fundamental wave disappears. (no large waves)
ESP switch: OFF2. Connect the oscilloscope to the test point TP522 (RFO) on theThis adjustment has to be performed upon replacing any of the
AVLS switch: NORMALMAIN board.following parts.
��� 0 V
HOLD switch: OFF3. Move the optical pick-up to the center by pressing the +Y Optical pick-up
and = keys.Y RV503 (Focus gain VR)
Before Beginning Adjustment4. Put the disc. (YEDS-18)Y RV502 (Tracking gain VR)Fig. 2
Set the equipment to service mode (See page 8) and check the5. Press the ^ key.
Normally, be sure not to move RV503 (focus gain VR) and
following. If there is an error, repair the equipment.From focus searching, focus is turned ON while enteringY Waveform with no traverse waveform during 100 track jump.
RV502 (tracking gain VR).
CLV drawing-in mode. Tracking and sled are turned OFF.(Brake application is smooth because of adjustment)
Y Checking of the sled motor6. Press the PLAY MODE key. (Both tracking and sled are turned
1. Open the upper panel.ON)Adjustment procedure:
2. Press the + and = keys and check that the optical pick-7. Check the oscilloscope waveform is as shown belo� Focus Gain Adjustment �w.
up can move smoothly without sluggishness or abnorA good emal noiseye pattern means that the diamond shape (A) in theThis adjustment is not performed.��� 0 V
in innermost periphery n outermost periphery n innermostcenter of the waveform can be clearly distinguishedIf focus gain .VR RV503 is turned, set to mechanical center.
peripheryAdjustment Location: MAIN Board (See page 11)
+ : The optical pick-up moves outwardly.RF Signal Reference Waveform (Eye Pattern)
= : The optical pick-up moves inwardly.� Tracking Gain Adjustment �
VOLT/DIV : 200 mV (With the 10:1 probe in use) (perform at normal operation)
100 track jump waveformTP522
Y Checking of focus searching TIME/DIV : 500 ns
(RFO)
1. Open the upper panel.oscilloscopeFig. 3
(DC range)TP401
2. Press the ^ key. (Focus searching operation is activated con-
(VCC)
tinuously)Y Waveform with traverse waveform during 100 track jump.
MAIN board
3. Check the object lens of the optical pick-up for smooth up/10 k W(Brake application is poor because of adjustment)
RF levelTP (TE)
down motion without sluggishness or abnormal noise.+
0.8 to 1.2 Vp-pTP520 (VC)�
4. Press the p key.RV401
Check that focus searching operation is deactivated. If not,0.0022 ?F(See page 11)(VCC)
again press the p key slightly longer.
��� 0 V
1. Place the optical pick-up level, horizontally. (If the optical
To watch the eye pattern, set the oscilloscope to AC range and
VCC Adjustmentpick-up is not level, the 2-axis device will be weighted and
increase the vertical sensitivity of the oscilloscope for easy watch-
Adjustment Procedure:adjustment cannot be done)
ing.
digital voltmeter2. Connect the oscilloscope to TP (TE) and TP520 (VC) on the
(DC range)
MAIN board.
8. Stop revolving of the disc motor by pressing the p key.
MAIN board3. Set the disc (YEDS-18) and press the ^ key.
9. After the completion of adjustment, reset service mode. (See
4. Turn RV502 slightly clockwise (tracking gain drops) and ob-
page 8)
TP401 (VCC)+
tain a waveform with a fundamental wave (wavefor100 track jumpm has large
�traverse waveform
waveform
(See page 11)Check Location: MAIN Board (See page 11)waves) as in Figure 1.
5. Turn RV502 slowly counterclockwise (tracking gain rises) untilFig. 4
1. Set the equipment to service mode stop state. (See page 8)the fundamental wave disappears (no large waves) as in Fig-
RV503
2. Connect the digital voltmeter to TP401 (VCC) on the MAINure 2.Adjustment Location: MAIN Board (See page 11)
Focus Gain
board.6. Set RV502 to the position about 30u counterclockwise form
Adjustment
3. Adjust RV401 on the MAIN board so that the reading on digi-the position obtained in step 5. If RV502 contact point is moreTP520
tal voltmeter goes 2.77 V.than 90u counterclockwise from mechanical center, tracking(VC)TP
Specifications: 2.75 V to 2.8 Vgain is too high. In this case, readjust from step 4.(TE)RV502
4. After the completion of adjustment, reset service mode. (See7. Press + or = key and observe the 100 track jump wave-Tracking Gain
page 8)form. Check that no traverse waveform a+ppears for both Adjustment
or = directions. (See Figures 3 and 4)
Adjustment Location: MAIN Board (See page 11)It is acceptable if the traverse waveform appears only now and
then, but if it appears constantly, raise tracking gain slightly
and check step 7 again.
8. Check that there is not abnormal amount of operation noise
(white noise) from the 2-axis device. If there is, tracking gain
is too high, readjust starting with step 4.
� 9 �� 10 �� 11 �
Shopping Cart more
0 items
Log In
Reviews more
Write ReviewWrite a review on this product!
Payments
PayPal
PayPal
Information
Shipping & Returns
Privacy Notice
Conditions of Use
List of Manuals
Contact Us
What's New? more
D-R150SB
D-R150SB
Quick Start

$4.99
Current Parse Time: 0.099 s with 50 queries. Queries took 0.016454