Precautions for Checking Emission of Laser Diode[MAIN BOARD] (Conductor side)
Laser light of the equipment is focused by the object lens in the
optical pick-up so that the light focuses on the reflection surface of
the disc.
Therefore, be sure to keep your eyes more then 30cm apart from
the object lens when you check the emission of laser diode.
Laser Diode Checking Methods
During normal operation of the equipment, emission of the laser
diode is prohibited unless the upper panel is closed while turning
ON the S801 (push switch type).
The following two checking methods for the laser diode are operable.
Method-1 (In the service mode or normal operation) :
Emission of the laser diode is visually checked.
1. Open the upper lid.
2. Push the S801 as shown in Fig. 1 .
3. Check the object lens for confirming normal emission of the
laser diode. If not emitting, there is a trouble in the automatic
digital voltmeter
power control circuit or the optical pick-up. During normal
operation, the laser diode is turned ON about 2.5 seconds for
focus searching.TP506
+
�
TP547
S801
TP506Q501
Fig.1 Method to push S801
TP547
Method-2 (In the service mode or normal operation) :
Check the value of current flowing in the laser diode.
1. Remove the upper panel.
2. Read the current printed on the rear side of the optical pick-up.
(Print on the rear side of the optical pick-up)Fig.2 Digital Voltmeter Connecting Location
AC2211397
current valueyear
A : less than 48 mAmonth
date
shift No.
line No.
version
3. Connect a level meter as shown in Fig. 2
4. Press the ^ key.
5. Calculate the current value by the reading of the digital voltmeter
Reading of the tester (V) ¸ 4.7 ( W ) = current value (A)
(Example) Reading of the digital voltmeter of 0.2256 V :
0.2256 V ¸ 4.7 W = 0.048 (A) = 48 mA
6. Check that the current value is within the following range.
+5
Y Current value of the label mA(25�11°C)
Variation by temperature : 0.4mA°C /
Current increases with as temperature increases.
Current decreases with as temperature decreases.
If the current is more than the range above, there is a trouble in the
automatic power control circuit or the laser diode is in deterioration.
If less than the range, a trouble exists in the automatic power control
circuit or the optical pick-up.
N 4 N |